Method for evaluation of ionic interactions in liquid chromatography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F20%3A10416653" target="_blank" >RIV/00216208:11310/20:10416653 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=x9JIar7PU1" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=x9JIar7PU1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2020.461301" target="_blank" >10.1016/j.chroma.2020.461301</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Method for evaluation of ionic interactions in liquid chromatography
Popis výsledku v původním jazyce
In this work we utilized basic and acidic analytes to investigate the ionic interaction participation in retention behavior of selected reversed-phase and polar columns. The test analytes included nitrate, benzenesulfonate and trimethylphenylammonium ions. The fully aqueous mobile phase comprising 10 mM dichloroacetic acid buffered with ammonia solution to desirable pH was used for retention experiments. Developed method was utilized to study the ionic interactions of stationary phases in pH range between 2.5 and 9.0. We demonstrate that selected sorbents used for reversed-phase and hydrophilic interaction chromatography separations exhibit cation- or anion-exchange interactions. We compare the results to novel Atlantis PREMIER BEH C18 AX mixed-mode column that combines reversed-phase and anion-exchange interaction modes. We evaluated the relative retention strength of selected columns for anionic and cationic analytes.
Název v anglickém jazyce
Method for evaluation of ionic interactions in liquid chromatography
Popis výsledku anglicky
In this work we utilized basic and acidic analytes to investigate the ionic interaction participation in retention behavior of selected reversed-phase and polar columns. The test analytes included nitrate, benzenesulfonate and trimethylphenylammonium ions. The fully aqueous mobile phase comprising 10 mM dichloroacetic acid buffered with ammonia solution to desirable pH was used for retention experiments. Developed method was utilized to study the ionic interactions of stationary phases in pH range between 2.5 and 9.0. We demonstrate that selected sorbents used for reversed-phase and hydrophilic interaction chromatography separations exhibit cation- or anion-exchange interactions. We compare the results to novel Atlantis PREMIER BEH C18 AX mixed-mode column that combines reversed-phase and anion-exchange interaction modes. We evaluated the relative retention strength of selected columns for anionic and cationic analytes.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA20-19655S" target="_blank" >GA20-19655S: Strategie pro on-line štěpení proteinů s následnou separací v mix-mode chromatografii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1625
Číslo periodika v rámci svazku
August
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
461301
Kód UT WoS článku
000552017600038
EID výsledku v databázi Scopus
2-s2.0-85086145823