Spectrometric determination of trimethoprim and sulfamethoxazole in tablets by automated sequential injection technique
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F20%3A10423509" target="_blank" >RIV/00216208:11310/20:10423509 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ESfs0p3Ryl" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ESfs0p3Ryl</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-020-02631-4" target="_blank" >10.1007/s00706-020-02631-4</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Spectrometric determination of trimethoprim and sulfamethoxazole in tablets by automated sequential injection technique
Popis výsledku v původním jazyce
An automated sequential injection analysis with spectrometric detection for the determination of trimethoprim and sulfamethoxazole in tablets is proposed. The concentration of sulfamethoxazole is determined by monitoring the absorbance at 540 nm due to the intensively colored complex formed by derivatization reaction of sulfamethoxazole with nitrite and N-(1-naphthyl)ethylenediamine in acidic media. With knowledge of the sulfamethoxazole concentration, the trimethoprim concentration can be calculated from the absorption of the sample solution at 264 nm, where both analytes absorb, and the additivity of individual absorbances according to Beer-Lambert law can be used. The developed method has a linear dynamic range of 0.03-5.0 mg dm(-3) and a detection limit of 0.03 mg dm(-3) for trimethoprim and a linear dynamic range of 0.1-10.0 mg dm(-3) and a detection limit of 0.01 mg dm(-3) for sulfamethoxazole. The sampling frequency of the method is 24 h(-1). The method was successfully applied on pharmaceutical dosage form of tablets, as the results of the determination are in a good agreement with the official pharmacopoeial method (HPLC). The developed sequential injection analysis is simpler, cheaper, and faster than already published methods and pharmacopoeial assay. So it appears to be suitable for quality control in the pharmaceutical industry.
Název v anglickém jazyce
Spectrometric determination of trimethoprim and sulfamethoxazole in tablets by automated sequential injection technique
Popis výsledku anglicky
An automated sequential injection analysis with spectrometric detection for the determination of trimethoprim and sulfamethoxazole in tablets is proposed. The concentration of sulfamethoxazole is determined by monitoring the absorbance at 540 nm due to the intensively colored complex formed by derivatization reaction of sulfamethoxazole with nitrite and N-(1-naphthyl)ethylenediamine in acidic media. With knowledge of the sulfamethoxazole concentration, the trimethoprim concentration can be calculated from the absorption of the sample solution at 264 nm, where both analytes absorb, and the additivity of individual absorbances according to Beer-Lambert law can be used. The developed method has a linear dynamic range of 0.03-5.0 mg dm(-3) and a detection limit of 0.03 mg dm(-3) for trimethoprim and a linear dynamic range of 0.1-10.0 mg dm(-3) and a detection limit of 0.01 mg dm(-3) for sulfamethoxazole. The sampling frequency of the method is 24 h(-1). The method was successfully applied on pharmaceutical dosage form of tablets, as the results of the determination are in a good agreement with the official pharmacopoeial method (HPLC). The developed sequential injection analysis is simpler, cheaper, and faster than already published methods and pharmacopoeial assay. So it appears to be suitable for quality control in the pharmaceutical industry.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte für Chemie - Chemical Monthly
ISSN
0026-9247
e-ISSN
—
Svazek periodika
151
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
6
Strana od-do
1311-1316
Kód UT WoS článku
000537679200003
EID výsledku v databázi Scopus
2-s2.0-85085975314