The perspectives of Relative Response Factors tabulation while alcoholic products analysis with GC-MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F21%3A10442099" target="_blank" >RIV/00216208:11310/21:10442099 - isvavai.cz</a>
Výsledek na webu
<a href="http://web.natur.cuni.cz/analchem/isc/isc17.pdf" target="_blank" >http://web.natur.cuni.cz/analchem/isc/isc17.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The perspectives of Relative Response Factors tabulation while alcoholic products analysis with GC-MS
Popis výsledku v původním jazyce
This work assesses the use of relative response factors (RRFs) for the quality control of alcoholic products by GC-MS, using two internal standard (IS) methods. A standard IS method using 1-pentanol was compared with an "Ethanol as IS" method. The stability of RRF values for both methods was tested using standard solutions based on 20, 40, and 96% ethanol-water matrices. Within these three matrices, solutions of the ten most abundant volatile compounds were analyzed at four different concentrations (250, 500, 1000, and 5000 mg L-1 absolute alcohol, AA). Each solution was measured four times by GC-MS in SIM mode under repeatability conditions. Our results showed that the relative standard deviations of RRFs for all concentrations were found to be 8% for the standard method and 40% for the ethanol method.
Název v anglickém jazyce
The perspectives of Relative Response Factors tabulation while alcoholic products analysis with GC-MS
Popis výsledku anglicky
This work assesses the use of relative response factors (RRFs) for the quality control of alcoholic products by GC-MS, using two internal standard (IS) methods. A standard IS method using 1-pentanol was compared with an "Ethanol as IS" method. The stability of RRF values for both methods was tested using standard solutions based on 20, 40, and 96% ethanol-water matrices. Within these three matrices, solutions of the ten most abundant volatile compounds were analyzed at four different concentrations (250, 500, 1000, and 5000 mg L-1 absolute alcohol, AA). Each solution was measured four times by GC-MS in SIM mode under repeatability conditions. Our results showed that the relative standard deviations of RRFs for all concentrations were found to be 8% for the standard method and 40% for the ethanol method.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 17th International Students Conference "Modern Analytical Chemistry"
ISBN
978-80-7444-089-2
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
234-239
Název nakladatele
Univerzita Karlova, Přírodovědecká fakulta
Místo vydání
Praha
Místo konání akce
Prague
Datum konání akce
16. 9. 2021
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—