Detection of Pyocyanin with a Boron-doped Diamond Electrode Using Flow Injection Analysis with Amperometric Detection and Square Wave Voltammetry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F22%3A10435898" target="_blank" >RIV/00216208:11310/22:10435898 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=qPwhmOgxvJ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=qPwhmOgxvJ</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.202100562" target="_blank" >10.1002/elan.202100562</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Detection of Pyocyanin with a Boron-doped Diamond Electrode Using Flow Injection Analysis with Amperometric Detection and Square Wave Voltammetry
Popis výsledku v původním jazyce
We report on the analytical performance of boron-doped diamond thin-film electrodes for the detection of the virulence factor, pyocyanin (PYO). The results reported herein confirm the utility of diamond electrodes for the sensitive and reproducible detection of pyocyanin in a 0.1 mol L(-1) phosphate buffer (pH 7.4) when using amperometric detection coupled with flow injection analysis (FIA) or square wave voltammetry (SWV). Pyocyanin was reductively detected by hydrodynamic voltammetry in FIA at an E(1/2) of -0.31 V vs. Ag/AgCl (3 mol L(-1) KCl). The detection figures of merit were a linear dynamic range from 100 to 0.08 μmol L(-1), a response reproducibility of 1.3 % (RSD), and a limit of detection of 0.09 μmol L(-1) (S/N=3). A comparable linear dynamic range, response reproducibility and limit of detection were observed in preliminary square wave voltammetry measurements. Importantly, these detection figures of merit were obtained using boron-doped diamond electrodes that received no conventional pretreatment. Some comparison data are presented for nitrogen-incorporated tetrahedral amorphous carbon (ta-C:N) and glassy carbon (GC) electrodes.
Název v anglickém jazyce
Detection of Pyocyanin with a Boron-doped Diamond Electrode Using Flow Injection Analysis with Amperometric Detection and Square Wave Voltammetry
Popis výsledku anglicky
We report on the analytical performance of boron-doped diamond thin-film electrodes for the detection of the virulence factor, pyocyanin (PYO). The results reported herein confirm the utility of diamond electrodes for the sensitive and reproducible detection of pyocyanin in a 0.1 mol L(-1) phosphate buffer (pH 7.4) when using amperometric detection coupled with flow injection analysis (FIA) or square wave voltammetry (SWV). Pyocyanin was reductively detected by hydrodynamic voltammetry in FIA at an E(1/2) of -0.31 V vs. Ag/AgCl (3 mol L(-1) KCl). The detection figures of merit were a linear dynamic range from 100 to 0.08 μmol L(-1), a response reproducibility of 1.3 % (RSD), and a limit of detection of 0.09 μmol L(-1) (S/N=3). A comparable linear dynamic range, response reproducibility and limit of detection were observed in preliminary square wave voltammetry measurements. Importantly, these detection figures of merit were obtained using boron-doped diamond electrodes that received no conventional pretreatment. Some comparison data are presented for nitrogen-incorporated tetrahedral amorphous carbon (ta-C:N) and glassy carbon (GC) electrodes.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
1521-4109
Svazek periodika
34
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
11
Strana od-do
1902-1912
Kód UT WoS článku
000741283700001
EID výsledku v databázi Scopus
2-s2.0-85122749234