Capillary monolithic columns based on poly(styrene-divinylbenzene-methacrylic acid) copolymer for liquid chromatography and electrochromatography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F22%3A10452229" target="_blank" >RIV/00216208:11310/22:10452229 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=B31hdNpNDC" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=B31hdNpNDC</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-022-02944-6" target="_blank" >10.1007/s00706-022-02944-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Capillary monolithic columns based on poly(styrene-divinylbenzene-methacrylic acid) copolymer for liquid chromatography and electrochromatography
Popis výsledku v původním jazyce
This work deals with newly developed poly(styrene-divinylbenzene-methacrylic acid) monolithic columns for capillary electrochromatographic and capillary liquid chromatographic separations of low-molecular-weight organic compounds. The influence of the polymerization time on chromatographic properties of prepared monolithic capillary columns was studied by capillary electrochromatography and capillary liquid chromatography using a model mixture of thiourea, benzene, and its homologues. The effect of electrostatic interactions between methacrylic acid as a weak cation-exchanger and selected analytes (a mixture of three amino acids, and thiourea, or diethylamine) on their retention in capillary liquid chromatography was investigated. The determined run-to-run and batch-to-batch repeatabilities indicate high reliability of the preparation of the separation media.
Název v anglickém jazyce
Capillary monolithic columns based on poly(styrene-divinylbenzene-methacrylic acid) copolymer for liquid chromatography and electrochromatography
Popis výsledku anglicky
This work deals with newly developed poly(styrene-divinylbenzene-methacrylic acid) monolithic columns for capillary electrochromatographic and capillary liquid chromatographic separations of low-molecular-weight organic compounds. The influence of the polymerization time on chromatographic properties of prepared monolithic capillary columns was studied by capillary electrochromatography and capillary liquid chromatography using a model mixture of thiourea, benzene, and its homologues. The effect of electrostatic interactions between methacrylic acid as a weak cation-exchanger and selected analytes (a mixture of three amino acids, and thiourea, or diethylamine) on their retention in capillary liquid chromatography was investigated. The determined run-to-run and batch-to-batch repeatabilities indicate high reliability of the preparation of the separation media.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte für Chemie - Chemical Monthly
ISSN
0026-9247
e-ISSN
1434-4475
Svazek periodika
153
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
7
Strana od-do
759-765
Kód UT WoS článku
000825170700002
EID výsledku v databázi Scopus
2-s2.0-85134295277