Impact of column selection for the analysis of 3mer phosphorothioated oligonucleotides in hydrophilic interaction liquid chromatography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F25%3A10504279" target="_blank" >RIV/00216208:11310/25:10504279 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ksy1hMMXKM" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ksy1hMMXKM</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2025.466404" target="_blank" >10.1016/j.chroma.2025.466404</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Impact of column selection for the analysis of 3mer phosphorothioated oligonucleotides in hydrophilic interaction liquid chromatography
Popis výsledku v původním jazyce
With advancing development of therapeutic oligonucleotides, the demand for chromatographic methods for analysis and identification of oligonucleotide impurities and metabolites increases. 3mer oligonucleotides selected for this study represent common metabolites of nusinersen (drug Spinraza), in terms of length, sequence and phosphorothioate modifications. The aim of this work is to investigate the hydrophilic interaction liquid chromatography applicability to analysis of short 3mer oligonucleotides. Their ability to suppress diastereomeric separation and to resolve oligonucleotides differing in one nucleobase at different position in the sequence (3'end, 5'end, middle) was evaluated. The effects of the 3mer sequence and chromatographic conditions (pH of the aqueous part of the mobile phase, buffer concentration, column temperature) on the oligonucleotides' separation according to their sequence ("sequence selectivity") and peak broadening due to diastereomeric separation were investigated for selected zwitterionic columns, diol column, amide column, and two chiral columns (cyclofructan-and quinine-based). The zwitterionic stationary phases showed a great potential for analysis of short oligonucleotides. Diol column showed partial separation of diastereomers, interfering with the sequence-based oligonucleotides resolution due the peak broadening under all tested conditions.
Název v anglickém jazyce
Impact of column selection for the analysis of 3mer phosphorothioated oligonucleotides in hydrophilic interaction liquid chromatography
Popis výsledku anglicky
With advancing development of therapeutic oligonucleotides, the demand for chromatographic methods for analysis and identification of oligonucleotide impurities and metabolites increases. 3mer oligonucleotides selected for this study represent common metabolites of nusinersen (drug Spinraza), in terms of length, sequence and phosphorothioate modifications. The aim of this work is to investigate the hydrophilic interaction liquid chromatography applicability to analysis of short 3mer oligonucleotides. Their ability to suppress diastereomeric separation and to resolve oligonucleotides differing in one nucleobase at different position in the sequence (3'end, 5'end, middle) was evaluated. The effects of the 3mer sequence and chromatographic conditions (pH of the aqueous part of the mobile phase, buffer concentration, column temperature) on the oligonucleotides' separation according to their sequence ("sequence selectivity") and peak broadening due to diastereomeric separation were investigated for selected zwitterionic columns, diol column, amide column, and two chiral columns (cyclofructan-and quinine-based). The zwitterionic stationary phases showed a great potential for analysis of short oligonucleotides. Diol column showed partial separation of diastereomers, interfering with the sequence-based oligonucleotides resolution due the peak broadening under all tested conditions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
1873-3778
Svazek periodika
1761
Číslo periodika v rámci svazku
October
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
466404
Kód UT WoS článku
001586015700003
EID výsledku v databázi Scopus
2-s2.0-105016847850