Langmuir Probe Diagnostics of DC Hollow Cathode Discharge in 1 kHz Pulsed Regime
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F09%3A00206835" target="_blank" >RIV/00216208:11320/09:00206835 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Langmuir Probe Diagnostics of DC Hollow Cathode Discharge in 1 kHz Pulsed Regime
Popis výsledku v původním jazyce
The pulsed DC hollow cathode discharge has been studied in the low pressure plasma jet sputtering system by means of cylindrical Langmuir probe. Measurements have been performed in pure Ar with the flow rate of 30 sccm. The repetition frequency of the pulses of 1 kHz has been chosen with the pulse width 100 mis (duty cycle 10%) and the amplitude of the pulses was 400 V. The average discharge current reached about 250 mA. To obtain better stability of the discharge a 3.8 kOmega resistor was connected across the pulse switch. Consequently, there was a weak continuous dc discharge on the background of the pulsed discharge. From the probe characteristics the plasma and floating potential, electron density and electron temperature have been evaluated. Theirdependences on the pressure (in the range of several Pa) and on the radial distance from the central axis of the system are presented. Temporal resolution of the measurements is 0.5 mis.
Název v anglickém jazyce
Langmuir Probe Diagnostics of DC Hollow Cathode Discharge in 1 kHz Pulsed Regime
Popis výsledku anglicky
The pulsed DC hollow cathode discharge has been studied in the low pressure plasma jet sputtering system by means of cylindrical Langmuir probe. Measurements have been performed in pure Ar with the flow rate of 30 sccm. The repetition frequency of the pulses of 1 kHz has been chosen with the pulse width 100 mis (duty cycle 10%) and the amplitude of the pulses was 400 V. The average discharge current reached about 250 mA. To obtain better stability of the discharge a 3.8 kOmega resistor was connected across the pulse switch. Consequently, there was a weak continuous dc discharge on the background of the pulsed discharge. From the probe characteristics the plasma and floating potential, electron density and electron temperature have been evaluated. Theirdependences on the pressure (in the range of several Pa) and on the radial distance from the central axis of the system are presented. Temporal resolution of the measurements is 0.5 mis.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
WDS´09 Proceedings of Contributed Papers: Part II - Physics of Plasmas and Ionized Media
ISBN
978-80-7378-102-6
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
Matfyzpress
Místo vydání
Prague
Místo konání akce
Prague
Datum konání akce
1. 1. 2009
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—