The BiPo-3 detector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F17%3A10371034" target="_blank" >RIV/00216208:11320/17:10371034 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/17:00310100
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.apradiso.2017.01.021" target="_blank" >http://dx.doi.org/10.1016/j.apradiso.2017.01.021</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.apradiso.2017.01.021" target="_blank" >10.1016/j.apradiso.2017.01.021</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The BiPo-3 detector
Popis výsledku v původním jazyce
The BiPo-3 detector is a low radioactive detector dedicated to measuring ultra-low natural contaminations of (TI)-T-208 and Bi-214 in thin materials, initially developed to measure the radiopurity of the double 13 decay source foils of the SuperNEMO experiment at the mu Bq/kg level. The BiPo-3 technique consists in installing the foil of interest between two thin ultra-radiopure scintillators coupled to low radioactive photomultipliers. The design and performances of the detector are presented. In this paper, the final results of the Tl-208 and Bi-214 activity measurements of the first enriched Se-82 foils are reported for the first time, showing the capability of the detector to reach sensitivities in the range of some mu Bq/kg.
Název v anglickém jazyce
The BiPo-3 detector
Popis výsledku anglicky
The BiPo-3 detector is a low radioactive detector dedicated to measuring ultra-low natural contaminations of (TI)-T-208 and Bi-214 in thin materials, initially developed to measure the radiopurity of the double 13 decay source foils of the SuperNEMO experiment at the mu Bq/kg level. The BiPo-3 technique consists in installing the foil of interest between two thin ultra-radiopure scintillators coupled to low radioactive photomultipliers. The design and performances of the detector are presented. In this paper, the final results of the Tl-208 and Bi-214 activity measurements of the first enriched Se-82 foils are reported for the first time, showing the capability of the detector to reach sensitivities in the range of some mu Bq/kg.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2015072" target="_blank" >LM2015072: Podzemní laboratoř LSM – účast České republiky</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
—
Svazek periodika
2017
Číslo periodika v rámci svazku
123
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
54-59
Kód UT WoS článku
000399854900011
EID výsledku v databázi Scopus
—