The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F17%3A10371043" target="_blank" >RIV/00216208:11320/17:10371043 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/17:00318695 RIV/68407700:21670/17:00318695
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1748-0221/12/06/P06002" target="_blank" >http://dx.doi.org/10.1088/1748-0221/12/06/P06002</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/12/06/P06002" target="_blank" >10.1088/1748-0221/12/06/P06002</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials
Popis výsledku v původním jazyce
The BiPo-3 detector, running at the Canfranc Underground Laboratory (LaboratorioSubterraneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of Tl-208 (Th-232 chain) and Bi-214 (U-238 chain) in thin materials. The total sensitive surface area of the detector is 3.6m(2). The detector has been developed to measure the radiopurity of the selenium double fi - decay source foils of the SuperNEMO experiment. In this paper the design and performance of the detector, and results of the background measurements in 208Tl and 214Bi, are presented, and the validation of the BiPo- 3 measurement with a calibrated aluminium foil is discussed. Results of the 208Tl and 214Bi activity measurements of the first enriched 82Se foils of the double fi - decay SuperNEMO experiment are reported. The sensitivity of the BiPo- 3 detector for the measurement of the SuperNEMO 82Se foils is A(Tl-208) < 2 mu Bq/kg (90% C. L.) and A(Bi-214) < 140 mu Bq/kg (90% C. L.) after 6 months of measurement.
Název v anglickém jazyce
The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials
Popis výsledku anglicky
The BiPo-3 detector, running at the Canfranc Underground Laboratory (LaboratorioSubterraneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of Tl-208 (Th-232 chain) and Bi-214 (U-238 chain) in thin materials. The total sensitive surface area of the detector is 3.6m(2). The detector has been developed to measure the radiopurity of the selenium double fi - decay source foils of the SuperNEMO experiment. In this paper the design and performance of the detector, and results of the background measurements in 208Tl and 214Bi, are presented, and the validation of the BiPo- 3 measurement with a calibrated aluminium foil is discussed. Results of the 208Tl and 214Bi activity measurements of the first enriched 82Se foils of the double fi - decay SuperNEMO experiment are reported. The sensitivity of the BiPo- 3 detector for the measurement of the SuperNEMO 82Se foils is A(Tl-208) < 2 mu Bq/kg (90% C. L.) and A(Bi-214) < 140 mu Bq/kg (90% C. L.) after 6 months of measurement.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2015072" target="_blank" >LM2015072: Podzemní laboratoř LSM – účast České republiky</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
2017
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
40
Strana od-do
—
Kód UT WoS článku
000405090600002
EID výsledku v databázi Scopus
—