Investigation of titanium grade (Ti-Gr) polycrystalline samples by high-resolution three-axis neutron diffractometer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F25%3A10510129" target="_blank" >RIV/00216208:11320/25:10510129 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=okkDO2wSlz" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=okkDO2wSlz</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.prostr.2025.10.034" target="_blank" >10.1016/j.prostr.2025.10.034</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Investigation of titanium grade (Ti-Gr) polycrystalline samples by high-resolution three-axis neutron diffractometer
Popis výsledku v původním jazyce
New focusing 3-axis diffractometer set-up equipped with the bent-perfect-crystal (BPC) monochromator and analyzer with the sample situated in between which has offered the sensitivity in determination of strains Δd/d < 10-4 in polycrystalline materials, has been introduced recently. The resolution determined by FWHM of the diffraction profiles is about one order of magnitude higher with respect to that of conventional 2-axis neutron strain/stress scanners. Therefore, the new set-up also offers the possibility of line profile analysis for relatively large irradiated gauge volumes and reasonable counting times, because the 3-axis set-up exploits focusing in real and momentum space simultaneously. The analysis is carried out by rocking the BPC analyzer, which provides the diffraction profile characterizing the sample. The neutron signal is registered by a point detector. In this case Titanium Grade 2 polycrystalline samples exposed to an external load by CONFORM-ECAP (C-E) and the Rotary Swaging (RS) were investigated. The influence of plastic deformation on the measured diffraction profiles is documented.
Název v anglickém jazyce
Investigation of titanium grade (Ti-Gr) polycrystalline samples by high-resolution three-axis neutron diffractometer
Popis výsledku anglicky
New focusing 3-axis diffractometer set-up equipped with the bent-perfect-crystal (BPC) monochromator and analyzer with the sample situated in between which has offered the sensitivity in determination of strains Δd/d < 10-4 in polycrystalline materials, has been introduced recently. The resolution determined by FWHM of the diffraction profiles is about one order of magnitude higher with respect to that of conventional 2-axis neutron strain/stress scanners. Therefore, the new set-up also offers the possibility of line profile analysis for relatively large irradiated gauge volumes and reasonable counting times, because the 3-axis set-up exploits focusing in real and momentum space simultaneously. The analysis is carried out by rocking the BPC analyzer, which provides the diffraction profile characterizing the sample. The neutron signal is registered by a point detector. In this case Titanium Grade 2 polycrystalline samples exposed to an external load by CONFORM-ECAP (C-E) and the Rotary Swaging (RS) were investigated. The influence of plastic deformation on the measured diffraction profiles is documented.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Procedia Structural Integrity
ISSN
2452-3216
e-ISSN
2452-3216
Svazek periodika
74
Číslo periodika v rámci svazku
Dec
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
56-61
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-105025025667