High-Resolution Residual Strain/Stress Measurements on Three Axis Neutron Diffractometer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F21%3A00551754" target="_blank" >RIV/61389005:_____/21:00551754 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scientific.net/AMR.1166.33" target="_blank" >https://www.scientific.net/AMR.1166.33</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.1166.33" target="_blank" >10.4028/www.scientific.net/AMR.1166.33</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High-Resolution Residual Strain/Stress Measurements on Three Axis Neutron Diffractometer
Popis výsledku v původním jazyce
Focusing 3-axis diffractometer set-up equipped with bent perfect crystal (BPC) monochromator and analyzer offers the sensitivity in determination of strains Dd/d < 10-4 in polycrystalline materials which is about one order of magnitude higher with respect to that of conventional 2-axis neutron scanners. It also offers possibility of line profile analysis for reasonable sample volumes and counting times. In this paper, the feasibility of using the 3-axis set-up even for measurements of rather large bulk polycrystalline samples with an acceptable resolution is presented. As the 3-axis set-up exploits focusing in real and momentum space, by a proper adjustment of the curvature of the analyzer, a high-resolution determination of the lattice changes can also be achieved even on large irradiated gauge volumes, though with a slightly relaxed resolution. It can be successfully exploited namely, in the strain/stress measurements on samples exposed to an external load, e.g. in tension/compression rig, in aging machine etc. In addition to the original performance where the analysis is carried out by rocking the BPC analyzer and the neutron signal registered by a point detector, a new alternative is offered which uses a fixed rocking angle position of the analyzer and the detector signal is registered by a one-dimensional position sensitive detector (PSD). This trick makes possible in some cases the elastic strain/stress measurements considerably faster and thus reduces the drawback of the time consuming step-by-step analysis.
Název v anglickém jazyce
High-Resolution Residual Strain/Stress Measurements on Three Axis Neutron Diffractometer
Popis výsledku anglicky
Focusing 3-axis diffractometer set-up equipped with bent perfect crystal (BPC) monochromator and analyzer offers the sensitivity in determination of strains Dd/d < 10-4 in polycrystalline materials which is about one order of magnitude higher with respect to that of conventional 2-axis neutron scanners. It also offers possibility of line profile analysis for reasonable sample volumes and counting times. In this paper, the feasibility of using the 3-axis set-up even for measurements of rather large bulk polycrystalline samples with an acceptable resolution is presented. As the 3-axis set-up exploits focusing in real and momentum space, by a proper adjustment of the curvature of the analyzer, a high-resolution determination of the lattice changes can also be achieved even on large irradiated gauge volumes, though with a slightly relaxed resolution. It can be successfully exploited namely, in the strain/stress measurements on samples exposed to an external load, e.g. in tension/compression rig, in aging machine etc. In addition to the original performance where the analysis is carried out by rocking the BPC analyzer and the neutron signal registered by a point detector, a new alternative is offered which uses a fixed rocking angle position of the analyzer and the detector signal is registered by a one-dimensional position sensitive detector (PSD). This trick makes possible in some cases the elastic strain/stress measurements considerably faster and thus reduces the drawback of the time consuming step-by-step analysis.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
AMR - Advanced Materials Research
ISSN
1662-8985
e-ISSN
—
Svazek periodika
1166
Číslo periodika v rámci svazku
SEP
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
8
Strana od-do
33-40
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—