High Resolution Residual Strain/Stress Measurements with a Three Axis Neutron Diffractometer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F20%3A00539698" target="_blank" >RIV/61389005:_____/20:00539698 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High Resolution Residual Strain/Stress Measurements with a Three Axis Neutron Diffractometer
Popis výsledku v původním jazyce
New unconventional high-resolution neutron diffraction 3-axis set-up for strain/stress measurements of rather large polycrystalline samples is presented. Contrary to the conventional 3-axis set-up carried out by rocking the analyser and the neutron signal registered by a point detector, this new alternative uses a fixed rocking angle position of the bent perfect crystal (BPC) analyser and the detector signal is registered by an one dimensional position sensitive detector (1-d PSD). As this set-up exploits focusing in momentum space, a high-resolution determination of the lattice changes is achieved even on large irradiated gauge volumes. This alternative can be successfully exploited, namely in the strain/stress measurements on samples exposed to an external load, e.g. in tension/compression rig.
Název v anglickém jazyce
High Resolution Residual Strain/Stress Measurements with a Three Axis Neutron Diffractometer
Popis výsledku anglicky
New unconventional high-resolution neutron diffraction 3-axis set-up for strain/stress measurements of rather large polycrystalline samples is presented. Contrary to the conventional 3-axis set-up carried out by rocking the analyser and the neutron signal registered by a point detector, this new alternative uses a fixed rocking angle position of the bent perfect crystal (BPC) analyser and the detector signal is registered by an one dimensional position sensitive detector (1-d PSD). As this set-up exploits focusing in momentum space, a high-resolution determination of the lattice changes is achieved even on large irradiated gauge volumes. This alternative can be successfully exploited, namely in the strain/stress measurements on samples exposed to an external load, e.g. in tension/compression rig.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings IFR2020
ISBN
978-989-54756-1-2
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
757-758
Název nakladatele
INEGI
Místo vydání
Porto
Místo konání akce
online
Datum konání akce
6. 9. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000731040500144