Biomechanical Response of Head during Impact Loading
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11510%2F10%3A10080691" target="_blank" >RIV/00216208:11510/10:10080691 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biomechanical Response of Head during Impact Loading
Popis výsledku v původním jazyce
Biomechanical response of head during impact loading presents a globally accented issue associated mainly with the passive vehicle safety. Based on detection of the dynamic values and biomaterial characteristics during the head impact loading are we ableto observe the biomechanical response of biological structures to the loading. We have used mathematical and physical models for the computational tasks of inverse dynamics that allow us to solve interactional biomechanical conditions in both real and extrapolated extremely-loading situations. Based on changes of input mechanical loading we have been able to determine appropriate biomechanical reaction and specify the value of the HIC which can be approximately correlated to the AIS using a table. Gathered knowledge can be applied to all the situations when a head hits an obstacle. The mechanisms relate well to the ?injury? issues during both work and free time activities like transportation, sports etc.
Název v anglickém jazyce
Biomechanical Response of Head during Impact Loading
Popis výsledku anglicky
Biomechanical response of head during impact loading presents a globally accented issue associated mainly with the passive vehicle safety. Based on detection of the dynamic values and biomaterial characteristics during the head impact loading are we ableto observe the biomechanical response of biological structures to the loading. We have used mathematical and physical models for the computational tasks of inverse dynamics that allow us to solve interactional biomechanical conditions in both real and extrapolated extremely-loading situations. Based on changes of input mechanical loading we have been able to determine appropriate biomechanical reaction and specify the value of the HIC which can be approximately correlated to the AIS using a table. Gathered knowledge can be applied to all the situations when a head hits an obstacle. The mechanisms relate well to the ?injury? issues during both work and free time activities like transportation, sports etc.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
AM - Pedagogika a školství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP407%2F10%2F1624" target="_blank" >GAP407/10/1624: Identifikace limitních účinků hypokinetické enviromentální zátěže na spolehlivost senzomotorických reakcí člověka</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Transactions on Transport Sciences
ISSN
1802-971X
e-ISSN
—
Svazek periodika
3
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
13
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—