In vivo assessment of time dependent changes of T2*in medial meniscus under loading at 3T: A preliminary study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11510%2F18%3A10375691" target="_blank" >RIV/00216208:11510/18:10375691 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00023884:_____/18:00007910
Výsledek na webu
<a href="https://doi.org/10.1016/j.jab.2017.12.001" target="_blank" >https://doi.org/10.1016/j.jab.2017.12.001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jab.2017.12.001" target="_blank" >10.1016/j.jab.2017.12.001</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In vivo assessment of time dependent changes of T2*in medial meniscus under loading at 3T: A preliminary study
Popis výsledku v původním jazyce
Due to the internal structure of the knee joint, the ability to characterize and quantify the dynamic response of the meniscal tissue directly in vivo is highly problematic. The main purpose of this study was to investigate the behaviour of the meniscus under loading conditions. Four healthy young females were included. To obtain T2* values in the meniscus, the vTE sequence was used with 10 echoes ranging from 0.8 to 10.1 ms. Submilisecond first echo time is a great advantage of vTE sequence allowing for precise mapping of relatively short T2*. The two-parametric least squares fitting procedure was used to calculate T2* pixel-wise. A custom-made diamagnetic apparatus was developed to simulate stress conditions on the lower limb in a conventional MR scanner. vTE T2* was performed in five consecutive scans, 6:10 min apart. Three different compartments of the medial and lateral meniscus were segmented. The differences at the different time-points were calculated. A constant increase of T2* times after compression was statistically significant in the anterior horn of the medial meniscus. T2* mapping with variable echo time sequence might be a satisfactorily sensitive technique to detect the changes of meniscus physiology under loading conditions in vivo.
Název v anglickém jazyce
In vivo assessment of time dependent changes of T2*in medial meniscus under loading at 3T: A preliminary study
Popis výsledku anglicky
Due to the internal structure of the knee joint, the ability to characterize and quantify the dynamic response of the meniscal tissue directly in vivo is highly problematic. The main purpose of this study was to investigate the behaviour of the meniscus under loading conditions. Four healthy young females were included. To obtain T2* values in the meniscus, the vTE sequence was used with 10 echoes ranging from 0.8 to 10.1 ms. Submilisecond first echo time is a great advantage of vTE sequence allowing for precise mapping of relatively short T2*. The two-parametric least squares fitting procedure was used to calculate T2* pixel-wise. A custom-made diamagnetic apparatus was developed to simulate stress conditions on the lower limb in a conventional MR scanner. vTE T2* was performed in five consecutive scans, 6:10 min apart. Three different compartments of the medial and lateral meniscus were segmented. The differences at the different time-points were calculated. A constant increase of T2* times after compression was statistically significant in the anterior horn of the medial meniscus. T2* mapping with variable echo time sequence might be a satisfactorily sensitive technique to detect the changes of meniscus physiology under loading conditions in vivo.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Applied Biomedicine
ISSN
1214-021X
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
138-144
Kód UT WoS článku
000429490500007
EID výsledku v databázi Scopus
2-s2.0-85039034656