Assessment of Postural Stability Using the Method of Postural Somatooscilography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11510%2F19%3A10392473" target="_blank" >RIV/00216208:11510/19:10392473 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/19:00340693 RIV/68407700:21720/19:00340693
Výsledek na webu
<a href="https://doi.org/10.1007/978-981-10-9038-7_129" target="_blank" >https://doi.org/10.1007/978-981-10-9038-7_129</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-981-10-9038-7_129" target="_blank" >10.1007/978-981-10-9038-7_129</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of Postural Stability Using the Method of Postural Somatooscilography
Popis výsledku v původním jazyce
The aim of article is to present new method for evaluating the postural stability using oscillating platform. Proposed methods are alternative to basic methods which are usually parts of the commercial posturography systems. The methods for calculating the postural parameters have been designed in order to objectively quantify and classify the ability of postural stabilization on a standardized oscillatory platform, and determine differences in the postural stabilization of motor function in healthy people and in people with postural instability. The Posturomed (Haider Bioswing GmbH) and biaxial accelerometer sensor were used for measurement the body acceleration during single leg stance provocation test. The postural somatooscilogram has been defined, which shows accelerations of platform, in horizontal plane in both anteroposterior and mediolateral directions over time. Two parameters, Average Damping Coefficient (ADC) and Average Coefficient of Damped Energy (ACDE), were used to evaluate postural stability. The proposed method was implemented in MatLab sw. Patients with postural disorders and control group of healthy subjects were measured. Statistically significant differences have been observed in postural stability between independent postural stable group and postural unstable groups. Based on the findings, we can say that the presented method allows a complex analysis of the single leg stance in patients with postural balance disorders in clinical practice.
Název v anglickém jazyce
Assessment of Postural Stability Using the Method of Postural Somatooscilography
Popis výsledku anglicky
The aim of article is to present new method for evaluating the postural stability using oscillating platform. Proposed methods are alternative to basic methods which are usually parts of the commercial posturography systems. The methods for calculating the postural parameters have been designed in order to objectively quantify and classify the ability of postural stabilization on a standardized oscillatory platform, and determine differences in the postural stabilization of motor function in healthy people and in people with postural instability. The Posturomed (Haider Bioswing GmbH) and biaxial accelerometer sensor were used for measurement the body acceleration during single leg stance provocation test. The postural somatooscilogram has been defined, which shows accelerations of platform, in horizontal plane in both anteroposterior and mediolateral directions over time. Two parameters, Average Damping Coefficient (ADC) and Average Coefficient of Damped Energy (ACDE), were used to evaluate postural stability. The proposed method was implemented in MatLab sw. Patients with postural disorders and control group of healthy subjects were measured. Statistically significant differences have been observed in postural stability between independent postural stable group and postural unstable groups. Based on the findings, we can say that the presented method allows a complex analysis of the single leg stance in patients with postural balance disorders in clinical practice.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018
ISBN
978-981-10-9038-7
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
5
Strana od-do
697-701
Název nakladatele
SPRINGER
Místo vydání
NEW YORK
Místo konání akce
Prague
Datum konání akce
3. 6. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000449742700129