Postural instability assessment using trunk acceleration frequency analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15510%2F16%3A33159454" target="_blank" >RIV/61989592:15510/16:33159454 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21260/16:00302701 RIV/68407700:21460/16:00302701
Výsledek na webu
<a href="http://dx.doi.org/10.1080/21679169.2016.1211174" target="_blank" >http://dx.doi.org/10.1080/21679169.2016.1211174</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/21679169.2016.1211174" target="_blank" >10.1080/21679169.2016.1211174</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Postural instability assessment using trunk acceleration frequency analysis
Popis výsledku v původním jazyce
The main tools for measuring postural instability of the body during quiet stance are stabilometric platforms. Frequency domain analysis of center of pressure excursions is used for detecting and quantifying specific diseases. The disadvantage of such platforms is their higher price and large dimensions. The main aim of this work was to identify the applicability of the frequency domain analysis of the trunk acceleration measured by one-axis accelerometer. In order to test the new technique, 10 patients with degenerative cerebellar ataxia and 11 healthy subjects were chosen to participate. The trunk acceleration of each subject with opened/closed eyes was measured during quiet stance on a firm/foam surface. The distribution of the power spectral density in the frequency spectrum of acceleration in the anterior-posterior direction is a suitable tool for quantifying postural instability. The percentages of the area under the power spectral density curve of middle frequency range (2.4-3.5 Hz) of acceleration in patients and healthy subjects were compared, and significant differences were found. The finding of our research is that a single cheap one-axis accelerometer placed on trunk to measure the acceleration in AP direction, together with the method based on the power spectral density of acceleration, could be a new tool for examinations of body instability.
Název v anglickém jazyce
Postural instability assessment using trunk acceleration frequency analysis
Popis výsledku anglicky
The main tools for measuring postural instability of the body during quiet stance are stabilometric platforms. Frequency domain analysis of center of pressure excursions is used for detecting and quantifying specific diseases. The disadvantage of such platforms is their higher price and large dimensions. The main aim of this work was to identify the applicability of the frequency domain analysis of the trunk acceleration measured by one-axis accelerometer. In order to test the new technique, 10 patients with degenerative cerebellar ataxia and 11 healthy subjects were chosen to participate. The trunk acceleration of each subject with opened/closed eyes was measured during quiet stance on a firm/foam surface. The distribution of the power spectral density in the frequency spectrum of acceleration in the anterior-posterior direction is a suitable tool for quantifying postural instability. The percentages of the area under the power spectral density curve of middle frequency range (2.4-3.5 Hz) of acceleration in patients and healthy subjects were compared, and significant differences were found. The finding of our research is that a single cheap one-axis accelerometer placed on trunk to measure the acceleration in AP direction, together with the method based on the power spectral density of acceleration, could be a new tool for examinations of body instability.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Journal of Physiotherapy
ISSN
2167-9169
e-ISSN
—
Svazek periodika
18
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
237-244
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84978951863