Whole-body dual-energy X-ray absorptiometry demonstrates better reliability than segmental body composition analysis in college-aged students
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11510%2F19%3A10394000" target="_blank" >RIV/00216208:11510/19:10394000 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17450/19:A2001ZOF
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=jo2FHTcMRh" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=jo2FHTcMRh</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1371/journal.pone.0215599" target="_blank" >10.1371/journal.pone.0215599</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Whole-body dual-energy X-ray absorptiometry demonstrates better reliability than segmental body composition analysis in college-aged students
Popis výsledku v původním jazyce
Dual-energy X-ray absorptiometry (DXA) is rapidly becoming more accessible and popular as a technique to monitor body composition. The reliability of DXA has been examined extensively using a number of different methodological approaches. This study sets up to investigate the accuracy of measuring the parameters of body composition (BC) by means of the whole-body and the segmental DXA method analysis with the typical error of measurement (TEM) that allows for expressing the error in the units of measure. The research was implemented in a group of 63 participants, all of whom were university students. Thirty-eight males (22.6+-2.9 years, average body mass 77.5+-8.4 kg) and 25 females (21.4+-2.0 years, average body mass 58.6+-7.2 kg) were recruited. The measured parameters included body mass (BM), fat-free mass (FFM), body fat (BF), bone mineral content (BMC), bone mineral density (BMD). For the whole-body analysis, the determined TEM was: BM at the level of 0.12 kg in females and 0.29 kg in males; BF 0.25kg and 0.44% females, 0.52 kg and 0.66% males; FFM 0.24 kg females and 0.42 kg males; BMC 0.02 kg females and males; BMD 0.01g/cm2 females and males. The TEM values in the segmental analysis were: BF within the range of 0.04-0.28 kg and 0.68-1.20% in females, 0.10-0.36 kg and 0.72-1.94% in males; FFM 0.08-0.41 kg females and 0.17-0.86 males, BMC 0.00-0.02 kg females and 0.01-0.02 kg males in relation to the body segment (upper limb, trunk, lower limb). The BMD value was at the level of 0.01-0.02g/cm2. The study results showed high reliability in measuring body composition parameters using the DXA method. The whole-body analysis showed a higher accuracy of measurement than the segmental. Only the changes that are greater than the TEM, or the upper bound (95%) of the confidence interval of the measurement can be considered demonstrable when interpreting repeated measurements.
Název v anglickém jazyce
Whole-body dual-energy X-ray absorptiometry demonstrates better reliability than segmental body composition analysis in college-aged students
Popis výsledku anglicky
Dual-energy X-ray absorptiometry (DXA) is rapidly becoming more accessible and popular as a technique to monitor body composition. The reliability of DXA has been examined extensively using a number of different methodological approaches. This study sets up to investigate the accuracy of measuring the parameters of body composition (BC) by means of the whole-body and the segmental DXA method analysis with the typical error of measurement (TEM) that allows for expressing the error in the units of measure. The research was implemented in a group of 63 participants, all of whom were university students. Thirty-eight males (22.6+-2.9 years, average body mass 77.5+-8.4 kg) and 25 females (21.4+-2.0 years, average body mass 58.6+-7.2 kg) were recruited. The measured parameters included body mass (BM), fat-free mass (FFM), body fat (BF), bone mineral content (BMC), bone mineral density (BMD). For the whole-body analysis, the determined TEM was: BM at the level of 0.12 kg in females and 0.29 kg in males; BF 0.25kg and 0.44% females, 0.52 kg and 0.66% males; FFM 0.24 kg females and 0.42 kg males; BMC 0.02 kg females and males; BMD 0.01g/cm2 females and males. The TEM values in the segmental analysis were: BF within the range of 0.04-0.28 kg and 0.68-1.20% in females, 0.10-0.36 kg and 0.72-1.94% in males; FFM 0.08-0.41 kg females and 0.17-0.86 males, BMC 0.00-0.02 kg females and 0.01-0.02 kg males in relation to the body segment (upper limb, trunk, lower limb). The BMD value was at the level of 0.01-0.02g/cm2. The study results showed high reliability in measuring body composition parameters using the DXA method. The whole-body analysis showed a higher accuracy of measurement than the segmental. Only the changes that are greater than the TEM, or the upper bound (95%) of the confidence interval of the measurement can be considered demonstrable when interpreting repeated measurements.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000798" target="_blank" >EF16_019/0000798: Healthy Aging in Industrial Environment HAIE</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
PLoS One
ISSN
1932-6203
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
15
Strana od-do
1-15
Kód UT WoS článku
000465087500034
EID výsledku v databázi Scopus
2-s2.0-85064828481