Role of TAT-system in cardiac excitability: investigation in a quantitative model of a ventricular cardiac cell
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F02%3A00007141" target="_blank" >RIV/00216224:14110/02:00007141 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Role of TAT-system in cardiac excitability: investigation in a quantitative model of a ventricular cardiac cell
Popis výsledku v původním jazyce
To explore the effect of the cardiac transverse axial tubular system (TAT-system) on excitability of ventricular cells, we developed a quantitative model incorporating the function of the tubules. The model was based on a modified quantitative description proposed by Luo and Rudy (Circ Res, 1994;74:1071-96). The modifications are summarized in our previous publication (Pásek M. et al. Scripta Medica, 2002;75:179-86). The morphological parameters of the TAT-system were based on the study of Soeller and Cannel (Circ Res, 1999;84:266-75). The time constants of ionic diffusion between the TAT-system and external solution was set to 250 ms for Ca2+ ions and 63 ms for K+ and Na+ ions. The properties of the tubular and peripheral membrane were set according to recently published data. The results of simulations were strongly affected by incorporation of the TAT-system under the conditions of low external [K+]. The model including TAT-system began to produce early after-depolarizations at cons
Název v anglickém jazyce
Role of TAT-system in cardiac excitability: investigation in a quantitative model of a ventricular cardiac cell
Popis výsledku anglicky
To explore the effect of the cardiac transverse axial tubular system (TAT-system) on excitability of ventricular cells, we developed a quantitative model incorporating the function of the tubules. The model was based on a modified quantitative description proposed by Luo and Rudy (Circ Res, 1994;74:1071-96). The modifications are summarized in our previous publication (Pásek M. et al. Scripta Medica, 2002;75:179-86). The morphological parameters of the TAT-system were based on the study of Soeller and Cannel (Circ Res, 1999;84:266-75). The time constants of ionic diffusion between the TAT-system and external solution was set to 250 ms for Ca2+ ions and 63 ms for K+ and Na+ ions. The properties of the tubular and peripheral membrane were set according to recently published data. The results of simulations were strongly affected by incorporation of the TAT-system under the conditions of low external [K+]. The model including TAT-system began to produce early after-depolarizations at cons
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP204%2F02%2FD129" target="_blank" >GP204/02/D129: Kvantitativní analýza vlivu tubulárního systému na elektrickou aktivitu srdečních buněk</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
New Frontiers in Basic Cardiovascular Research
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
47
Název nakladatele
Institute of Molecular Philosophy and Genetics, Slovak Academy of Science
Místo vydání
Smolenice
Místo konání akce
Smolenice
Datum konání akce
1. 1. 2002
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—