Srovnání tkáňové reakce během barvení napěťově citlivým barvivem u dvou zvířecích modelů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F05%3A00012663" target="_blank" >RIV/00216224:14110/05:00012663 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/05:00013062
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of the Tissue Response during the Loading with Voltage-Sensitive Dye in Two Animal Models
Popis výsledku v původním jazyce
Two animal models - guinea pig and rabbit - were used to record monophasic action potentials using voltage sensitive dye di-4-ANEPPS in isolated hearts perfused according to Langendorf. The hearts undergo the same isolation and loading procedures. Changes in electrogram and coronary flow are followed. During the loading and washout, prominent electrophysiological changes occur (mainly decrease of spontaneous heart rate and changes in the shape of T wave), accompanied with decrease in mean coronary flow.However, these changes differ in the two species. It may be concluded that rabbit heart is more resistant to the changes which are triggered with VSD application. Although these changes are partially reversible in guinea pig heart, this model seems to be more sensitive and thus less reliable.
Název v anglickém jazyce
Comparison of the Tissue Response during the Loading with Voltage-Sensitive Dye in Two Animal Models
Popis výsledku anglicky
Two animal models - guinea pig and rabbit - were used to record monophasic action potentials using voltage sensitive dye di-4-ANEPPS in isolated hearts perfused according to Langendorf. The hearts undergo the same isolation and loading procedures. Changes in electrogram and coronary flow are followed. During the loading and washout, prominent electrophysiological changes occur (mainly decrease of spontaneous heart rate and changes in the shape of T wave), accompanied with decrease in mean coronary flow.However, these changes differ in the two species. It may be concluded that rabbit heart is more resistant to the changes which are triggered with VSD application. Although these changes are partially reversible in guinea pig heart, this model seems to be more sensitive and thus less reliable.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Computers in Cardiology
ISBN
0-7803-9337-6
ISSN
0276-6574
e-ISSN
—
Počet stran výsledku
1
Strana od-do
—
Název nakladatele
Computers in Cardiology
Místo vydání
Lyon, Francie
Místo konání akce
Lyon
Datum konání akce
25. 9. 2005
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000236378300135