Electrophysiological Effects of Voltage Sensitive Dye di-4-ANNEPS in Rabbit and Guinea Pig Isolated Heart
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F10%3A00044669" target="_blank" >RIV/00216224:14110/10:00044669 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrophysiological Effects of Voltage Sensitive Dye di-4-ANNEPS in Rabbit and Guinea Pig Isolated Heart
Popis výsledku v původním jazyce
Voltage-sensitive dye (VSD) di-4-ANEPPS is currently used in our laboratory for recording of monophasic action potentials (MAPs) in isolated hearts. In this study, its electrophysiological effects on rabbit and guinea pig myocardium were compared duringstaining with VSD and washout from it. Electrograms were recorded and heart rate changes and the types and frequency of arrhythmias were evaluated. Althought certain electrophysiological changes were present in the hearts of both species, these changes are mostly reversible, especially in rabbit hearts. Thus, rabbit myocardium can be considered a reliable model for electrophysiological studies, especially when generation and propagation of the impulse is studied. It may be concluded that rabbit isolatedheart is more suitable model for electrophysiological studies in the isolated heart model than guinea pig heart.
Název v anglickém jazyce
Electrophysiological Effects of Voltage Sensitive Dye di-4-ANNEPS in Rabbit and Guinea Pig Isolated Heart
Popis výsledku anglicky
Voltage-sensitive dye (VSD) di-4-ANEPPS is currently used in our laboratory for recording of monophasic action potentials (MAPs) in isolated hearts. In this study, its electrophysiological effects on rabbit and guinea pig myocardium were compared duringstaining with VSD and washout from it. Electrograms were recorded and heart rate changes and the types and frequency of arrhythmias were evaluated. Althought certain electrophysiological changes were present in the hearts of both species, these changes are mostly reversible, especially in rabbit hearts. Thus, rabbit myocardium can be considered a reliable model for electrophysiological studies, especially when generation and propagation of the impulse is studied. It may be concluded that rabbit isolatedheart is more suitable model for electrophysiological studies in the isolated heart model than guinea pig heart.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F07%2F1473" target="_blank" >GA102/07/1473: Optické metody registrace elektrických potenciálů a koncentrace vápníku v srdci s laserovou stabilizací</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analysis of Biomedical Signals and Images
ISSN
1211-412X
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—