Model of Preconditioning in Guinea Pig and Rabbit Isolated Hearts Loaded with Voltage-Sensitive Dye Di-4-ANEPPS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F09%3A00044635" target="_blank" >RIV/00216224:14110/09:00044635 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Model of Preconditioning in Guinea Pig and Rabbit Isolated Hearts Loaded with Voltage-Sensitive Dye Di-4-ANEPPS
Popis výsledku v původním jazyce
Myocardial ischemia and reperfusion phenomena have been studied repeatedly in various models. The aim of this study was to verify preconditioning model in guinea pig and rabbit Langendorff-perfused hearts loaded with voltage-sensitive dye (VSD) di-4-ANEPPS which we use to record monophasic action potentials (MAPs) by optical method. The heart was perfused according to Langendorff at constant pressure (80mmHg) with Krebs Henseleit solution. Each experiment consisted of heart isolation, control perfusion,dye loading, washout and MAPs recording. Rabbit hearts loaded with VSD tolerated ischemia of longer duration without severe alterations of electrogram. Although the procedure of dye loading affects electrophysiological properties of the myocardium, in case of rabbit heart it is negligible (it is quite resistant to side effects of VSDs). In guinea pig mycardium, more cautiousness is needed.
Název v anglickém jazyce
Model of Preconditioning in Guinea Pig and Rabbit Isolated Hearts Loaded with Voltage-Sensitive Dye Di-4-ANEPPS
Popis výsledku anglicky
Myocardial ischemia and reperfusion phenomena have been studied repeatedly in various models. The aim of this study was to verify preconditioning model in guinea pig and rabbit Langendorff-perfused hearts loaded with voltage-sensitive dye (VSD) di-4-ANEPPS which we use to record monophasic action potentials (MAPs) by optical method. The heart was perfused according to Langendorff at constant pressure (80mmHg) with Krebs Henseleit solution. Each experiment consisted of heart isolation, control perfusion,dye loading, washout and MAPs recording. Rabbit hearts loaded with VSD tolerated ischemia of longer duration without severe alterations of electrogram. Although the procedure of dye loading affects electrophysiological properties of the myocardium, in case of rabbit heart it is negligible (it is quite resistant to side effects of VSDs). In guinea pig mycardium, more cautiousness is needed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Computers in Cardiology
ISBN
—
ISSN
0276-6574
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
ISSN
Místo vydání
Utah, USA
Místo konání akce
USA
Datum konání akce
15. 9. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000279344300133