Biomechanical evaluation of the MACSTL internal fixator for thoracic spinal stabilization.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F08%3A00107064" target="_blank" >RIV/00216224:14110/08:00107064 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.actavet.vfu.cz" target="_blank" >http://www.actavet.vfu.cz</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2754/avb200877010097" target="_blank" >10.2754/avb200877010097</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biomechanical evaluation of the MACSTL internal fixator for thoracic spinal stabilization.
Popis výsledku v původním jazyce
Unstable fractures of the thoracic spine represent a serious social and economic issue. They can lead to persistent consequences and chronic disease. The anatomical and biomechanical characteristics of the thoracic spine are different from all the other spinal parts due to its higher movability. The vertebrae of the chest area are less mobile conferring a higher degree of rigidity to the spine. To destabilize this relatively rigid system, a considerable force is necessary. The treatment of unstable spinal fractures is solely surgical. The decompression of the spinal canal with reposition and stabilization of the fracture is indicated urgently. This intervention is performed mostly from the posterior approach in the first phase. However, the anterior spinal column is the structure responsible for the stability of the spine. Therefore, the recent advances in spine surgery focus on this area of expertise. For this reason, we carried out a bio-mechanical study aimed at assessing the effectiveness of two surgical tactics used. The study consists in comparative experiments performed by computer aided device on segments of pig cadavers. The experiment involves a comparison of segments of thoracic spine under the following conditions: an anatomically intact segment, a spine segment with an artificially created anterior instability, and a segment with an applied internal fixator. The experiment compared the mechanical characteristics of these segments. The experiment has demonstrated that after application of the internal fixator used for stabilization of injured anterior spinal column at defined pre-loading of 200 N, the stability of damaged spinal segment in torsion increased twofold. It was also verified that sufficient stability can be ensured using the Modular Anterior Construct System (MACSTL) implant for ventral stabilization of thoracic spine unstable injuries. Endoscopic application of this implant represents an additional advantage of this surgical procedure.
Název v anglickém jazyce
Biomechanical evaluation of the MACSTL internal fixator for thoracic spinal stabilization.
Popis výsledku anglicky
Unstable fractures of the thoracic spine represent a serious social and economic issue. They can lead to persistent consequences and chronic disease. The anatomical and biomechanical characteristics of the thoracic spine are different from all the other spinal parts due to its higher movability. The vertebrae of the chest area are less mobile conferring a higher degree of rigidity to the spine. To destabilize this relatively rigid system, a considerable force is necessary. The treatment of unstable spinal fractures is solely surgical. The decompression of the spinal canal with reposition and stabilization of the fracture is indicated urgently. This intervention is performed mostly from the posterior approach in the first phase. However, the anterior spinal column is the structure responsible for the stability of the spine. Therefore, the recent advances in spine surgery focus on this area of expertise. For this reason, we carried out a bio-mechanical study aimed at assessing the effectiveness of two surgical tactics used. The study consists in comparative experiments performed by computer aided device on segments of pig cadavers. The experiment involves a comparison of segments of thoracic spine under the following conditions: an anatomically intact segment, a spine segment with an artificially created anterior instability, and a segment with an applied internal fixator. The experiment compared the mechanical characteristics of these segments. The experiment has demonstrated that after application of the internal fixator used for stabilization of injured anterior spinal column at defined pre-loading of 200 N, the stability of damaged spinal segment in torsion increased twofold. It was also verified that sufficient stability can be ensured using the Modular Anterior Construct System (MACSTL) implant for ventral stabilization of thoracic spine unstable injuries. Endoscopic application of this implant represents an additional advantage of this surgical procedure.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30211 - Orthopaedics
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ACTA VETERINARIA BRNO
ISSN
0001-7213
e-ISSN
—
Svazek periodika
77
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
97-102
Kód UT WoS článku
000255001500014
EID výsledku v databázi Scopus
—