Effects of Voltage-Sensitive Dye di-4-ANEPPS on Isolated Rat Heart Electrogram
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F11%3A00050213" target="_blank" >RIV/00216224:14110/11:00050213 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effects of Voltage-Sensitive Dye di-4-ANEPPS on Isolated Rat Heart Electrogram
Popis výsledku v původním jazyce
Although the classical suction microelectrodes are still considered golden standard for recording of monophasic action potentials, there are various new methods enabling to record electrical changes from small area on the heart surface. One of them is recording of cardiac electrical activity using voltage-sensitive dyes (VSDs) by optical method. VSDs exhibit large fluorescence and/or absorption changes that vary with changes of the membrane potential. Staining of the heart with the dye should not resultin pharmacological or toxic effects to the preparation. Data about response of the heart to staining with VSD are scarce. In order to determine this response in classical biomodel in basic cardiology, we followed arrythmia-preceding parameters in isolated rat heart electrogram during staining with VSD di-4-ANEPPS and washout periods.
Název v anglickém jazyce
Effects of Voltage-Sensitive Dye di-4-ANEPPS on Isolated Rat Heart Electrogram
Popis výsledku anglicky
Although the classical suction microelectrodes are still considered golden standard for recording of monophasic action potentials, there are various new methods enabling to record electrical changes from small area on the heart surface. One of them is recording of cardiac electrical activity using voltage-sensitive dyes (VSDs) by optical method. VSDs exhibit large fluorescence and/or absorption changes that vary with changes of the membrane potential. Staining of the heart with the dye should not resultin pharmacological or toxic effects to the preparation. Data about response of the heart to staining with VSD are scarce. In order to determine this response in classical biomodel in basic cardiology, we followed arrythmia-preceding parameters in isolated rat heart electrogram during staining with VSD di-4-ANEPPS and washout periods.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F07%2F1473" target="_blank" >GA102/07/1473: Optické metody registrace elektrických potenciálů a koncentrace vápníku v srdci s laserovou stabilizací</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Computing in Cardiology
ISSN
0276-6574
e-ISSN
—
Svazek periodika
38
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
721-724
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—