Tissue Response during Staining and Illumination of Voltage-Sensitive Dye in Rabbit Myocardium
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F07%3A00048140" target="_blank" >RIV/00216224:14110/07:00048140 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Tissue Response during Staining and Illumination of Voltage-Sensitive Dye in Rabbit Myocardium
Popis výsledku v původním jazyce
Voltage-sensitive dyes (VSD's) undergo changes in their electronic structure, and consequently their fluorescence spectra, in response to changes in the surrounding electric field and are therefore used for recording of monophasic action potentials (MAPs) by optical method in animal hearts. VSD di-4-ANEPPS is employed in our laboratory to record MAPs in isolated rabbit hearts perfused according to Langendorff with Krebs-Henseleit solution (K-H, 37C, 1, 25mM Ca2+). After stabilization (30min), the tissueis stained with di-4-ANEPPS (2mM) diluted in K-H (20-25min) and then washed-out with dye-free K-H (20-25min). Then measurement of MAPs is performed. So called photodynamic damage or phototoxic effects of VSDs have been reported under intense illumination, with alteration of electrical activity of the spontaneously beating heart. In order to determine whether this side effect is present in our experimental model, we followed electrogram, mean coronary flow and formation of hydroxyl radic
Název v anglickém jazyce
Tissue Response during Staining and Illumination of Voltage-Sensitive Dye in Rabbit Myocardium
Popis výsledku anglicky
Voltage-sensitive dyes (VSD's) undergo changes in their electronic structure, and consequently their fluorescence spectra, in response to changes in the surrounding electric field and are therefore used for recording of monophasic action potentials (MAPs) by optical method in animal hearts. VSD di-4-ANEPPS is employed in our laboratory to record MAPs in isolated rabbit hearts perfused according to Langendorff with Krebs-Henseleit solution (K-H, 37C, 1, 25mM Ca2+). After stabilization (30min), the tissueis stained with di-4-ANEPPS (2mM) diluted in K-H (20-25min) and then washed-out with dye-free K-H (20-25min). Then measurement of MAPs is performed. So called photodynamic damage or phototoxic effects of VSDs have been reported under intense illumination, with alteration of electrical activity of the spontaneously beating heart. In order to determine whether this side effect is present in our experimental model, we followed electrogram, mean coronary flow and formation of hydroxyl radic
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F07%2F1473" target="_blank" >GA102/07/1473: Optické metody registrace elektrických potenciálů a koncentrace vápníku v srdci s laserovou stabilizací</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Computers in Cardiology
ISBN
—
ISSN
0276-6574
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
Durham, USA
Místo konání akce
Durham, USA
Datum konání akce
30. 9. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—