Diagnostic Significance of a Mild Decrease of Baroreflex Sensitivity With Respect to Heart Rate in Type 1 Diabetes Mellitus
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F13%3A00071324" target="_blank" >RIV/00216224:14110/13:00071324 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Diagnostic Significance of a Mild Decrease of Baroreflex Sensitivity With Respect to Heart Rate in Type 1 Diabetes Mellitus
Popis výsledku v původním jazyce
Decreased baroreflex sensitivity is an early sign of autonomic dysfunction in patients with type-1 diabetes mellitus. We evaluated the repeatability of a mild baroreflex sensitivity decrease in diabetics with respect to their heart rate. Finger blood pressure was continuously recorded in 14 young diabetics without clinical signs of autonomic dysfunction and in 14 age-matched controls for 42 min. The recordings were divided into 3-min segments, and the mean inter-beat interval (IBI), baroreflex sensitivity in ms/mm Hg (BRS) and mHz/mm Hg (BRSf) were determined in each segment. These values fluctuated in each subject within 42 min and therefore coefficients of repeatability were calculated for all subjects. Diabetics compared with controls had a decreased mean BRS (p=0.05), a tendency to a shortened IBI (p=0.08), and a decreased BRSf (p=0.17). IBI correlated with BRS in diabetics (p=0.03); this correlation was at p=0.12 in the controls. BRSf was IBI independent (controls: p=0.81, diabeti
Název v anglickém jazyce
Diagnostic Significance of a Mild Decrease of Baroreflex Sensitivity With Respect to Heart Rate in Type 1 Diabetes Mellitus
Popis výsledku anglicky
Decreased baroreflex sensitivity is an early sign of autonomic dysfunction in patients with type-1 diabetes mellitus. We evaluated the repeatability of a mild baroreflex sensitivity decrease in diabetics with respect to their heart rate. Finger blood pressure was continuously recorded in 14 young diabetics without clinical signs of autonomic dysfunction and in 14 age-matched controls for 42 min. The recordings were divided into 3-min segments, and the mean inter-beat interval (IBI), baroreflex sensitivity in ms/mm Hg (BRS) and mHz/mm Hg (BRSf) were determined in each segment. These values fluctuated in each subject within 42 min and therefore coefficients of repeatability were calculated for all subjects. Diabetics compared with controls had a decreased mean BRS (p=0.05), a tendency to a shortened IBI (p=0.08), and a decreased BRSf (p=0.17). IBI correlated with BRS in diabetics (p=0.03); this correlation was at p=0.12 in the controls. BRSf was IBI independent (controls: p=0.81, diabeti
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
—
Svazek periodika
62
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
605-613
Kód UT WoS článku
000329167600003
EID výsledku v databázi Scopus
—