QUANTITATIVE ESTIMATION OF LEFT VENTRICULAR MYOCARDIAL PERFUSION BASED ON DYNAMIC CT SCANS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F13%3A00073085" target="_blank" >RIV/00216224:14110/13:00073085 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1515/bmt-2013-4288" target="_blank" >http://dx.doi.org/10.1515/bmt-2013-4288</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/bmt-2013-4288" target="_blank" >10.1515/bmt-2013-4288</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
QUANTITATIVE ESTIMATION OF LEFT VENTRICULAR MYOCARDIAL PERFUSION BASED ON DYNAMIC CT SCANS
Popis výsledku v původním jazyce
Computed tomography (CT) is considered an upcoming technology for the quantitative estimation of myocardial perfusion (MPF). Based on previous results that affirm the feasibility of estimating global MPF using a CT scanner in an animal model, this work evaluates the computation of MPF in patients by comparing two different mathematical approaches based on the indicator dilution method. The first, the so called upslope method, was already used in the previous study, the second uses a deconvolution modelwhich possibly is more suitable in the evaluation of regional MPF measurements. A good correlation between both methods could be found and the quantitative results of both methods correspond well to myocardial perfusion values as described in the literature.
Název v anglickém jazyce
QUANTITATIVE ESTIMATION OF LEFT VENTRICULAR MYOCARDIAL PERFUSION BASED ON DYNAMIC CT SCANS
Popis výsledku anglicky
Computed tomography (CT) is considered an upcoming technology for the quantitative estimation of myocardial perfusion (MPF). Based on previous results that affirm the feasibility of estimating global MPF using a CT scanner in an animal model, this work evaluates the computation of MPF in patients by comparing two different mathematical approaches based on the indicator dilution method. The first, the so called upslope method, was already used in the previous study, the second uses a deconvolution modelwhich possibly is more suitable in the evaluation of regional MPF measurements. A good correlation between both methods could be found and the quantitative results of both methods correspond well to myocardial perfusion values as described in the literature.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Engineering-Biomedizinische Technik
ISSN
0013-5585
e-ISSN
—
Svazek periodika
58
Číslo periodika v rámci svazku
Suppl. 1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
2
Strana od-do
1-2
Kód UT WoS článku
000329463600332
EID výsledku v databázi Scopus
—