Independent Component Analysis and Decision Trees for ECG Holter Recording De-Noising
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F14%3A00078730" target="_blank" >RIV/00216224:14110/14:00078730 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21230/14:00218088 RIV/68407700:21730/14:00218088 RIV/00159816:_____/14:00061098
Výsledek na webu
<a href="http://dx.doi.org/10.1371/journal.pone.0098450" target="_blank" >http://dx.doi.org/10.1371/journal.pone.0098450</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1371/journal.pone.0098450" target="_blank" >10.1371/journal.pone.0098450</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Independent Component Analysis and Decision Trees for ECG Holter Recording De-Noising
Popis výsledku v původním jazyce
We have developed a method focusing on ECG signal de-noising using Independent component analysis (ICA). This approach combines JADE source separation and binary decision tree for identification and subsequent ECG noise removal. In order to to test the efficiency of this method comparison to standard filtering a wavelet-based de-noising method was used. Freely data available at Physionet medical data storage were evaluated. Evaluation criteria was root mean square error (RMSE) between original ECG and filtered data contaminated with artificial noise. Proposed algorithm achieved comparable result in terms of standard noises (power line interference, base line wander, EMG), but noticeably significantly better results were achieved when uncommon noise (electrode cable movement artefact) were compared.
Název v anglickém jazyce
Independent Component Analysis and Decision Trees for ECG Holter Recording De-Noising
Popis výsledku anglicky
We have developed a method focusing on ECG signal de-noising using Independent component analysis (ICA). This approach combines JADE source separation and binary decision tree for identification and subsequent ECG noise removal. In order to to test the efficiency of this method comparison to standard filtering a wavelet-based de-noising method was used. Freely data available at Physionet medical data storage were evaluated. Evaluation criteria was root mean square error (RMSE) between original ECG and filtered data contaminated with artificial noise. Proposed algorithm achieved comparable result in terms of standard noises (power line interference, base line wander, EMG), but noticeably significantly better results were achieved when uncommon noise (electrode cable movement artefact) were compared.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Plos one
ISSN
1932-6203
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
"e98450"
Kód UT WoS článku
000341869000031
EID výsledku v databázi Scopus
—