The Effect of Voltage Sensitive Dye di-4-ANEPPS on the RT/RR Coupling in Rabbit Isolated Heart
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00081553" target="_blank" >RIV/00216224:14110/15:00081553 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Effect of Voltage Sensitive Dye di-4-ANEPPS on the RT/RR Coupling in Rabbit Isolated Heart
Popis výsledku v původním jazyce
Voltage sensitive dye (VSD) di-4-ANEPPS is ordinary used for optical measurement of action potential in experimental cardiology. In this work, the effect of the dye on the RT/RR coupling measured in electrograms (EG) recorded on rabbit isolated hearts was studied. The results were compared with the control experiments without VSD administration. The comparison was performed in preparation stage of the experiment that consisted of three phases: stabilization (S), VSD loading (L), and washout (W). The median and interquartile range (Q0.75-Q0.25) of the difference in RR, QT and RT/RR between the beginning and the end of the phases were computed and compared between the both groups.(RT/RR), in S, L and W, was -0.095, 0.061; -0.093, 0.043; -0.027, 0.039 indi-4-ANEPPS-treated group and -0.127, 0.071; 0.006, 0.016; -0.001, 0.025 in control group. The significant difference (P<0.01) was found between two groups in L phase. Additionally, there was the significant difference in RR [ms] which
Název v anglickém jazyce
The Effect of Voltage Sensitive Dye di-4-ANEPPS on the RT/RR Coupling in Rabbit Isolated Heart
Popis výsledku anglicky
Voltage sensitive dye (VSD) di-4-ANEPPS is ordinary used for optical measurement of action potential in experimental cardiology. In this work, the effect of the dye on the RT/RR coupling measured in electrograms (EG) recorded on rabbit isolated hearts was studied. The results were compared with the control experiments without VSD administration. The comparison was performed in preparation stage of the experiment that consisted of three phases: stabilization (S), VSD loading (L), and washout (W). The median and interquartile range (Q0.75-Q0.25) of the difference in RR, QT and RT/RR between the beginning and the end of the phases were computed and compared between the both groups.(RT/RR), in S, L and W, was -0.095, 0.061; -0.093, 0.043; -0.027, 0.039 indi-4-ANEPPS-treated group and -0.127, 0.071; 0.006, 0.016; -0.001, 0.025 in control group. The significant difference (P<0.01) was found between two groups in L phase. Additionally, there was the significant difference in RR [ms] which
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F12%2F2034" target="_blank" >GAP102/12/2034: Analýza vztahu mezi elektrickými ději a průtokem krve u srdečních komor</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Computing in Cardiology 2015
ISBN
—
ISSN
2325-8861
e-ISSN
—
Počet stran výsledku
4
Strana od-do
521-524
Název nakladatele
IEEE Computer Society
Místo vydání
Washington
Místo konání akce
Nice
Datum konání akce
1. 1. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—