Self-expandable biodegradable biliary stents in porcine model
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00082127" target="_blank" >RIV/00216224:14110/15:00082127 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60162694:G44__/15:43875243 RIV/62157124:16170/15:43873533 RIV/62157124:16810/15:43873533 RIV/65269705:_____/15:00062962
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jss.2014.08.006" target="_blank" >http://dx.doi.org/10.1016/j.jss.2014.08.006</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jss.2014.08.006" target="_blank" >10.1016/j.jss.2014.08.006</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Self-expandable biodegradable biliary stents in porcine model
Popis výsledku v původním jazyce
Background: Treatment or prevention of a benign biliary tree stricture is an unresolved problem. A novel self-expandable biodegradable polydioxanon biliary stent in a porcine model was studied. Materials and methods: This new stent was used in 23 pigs. Feasibility and safety of surgical stenting, time of biodegradation, and histologic reaction in 2, 8, 13, and 20 wk of a follow-up were studied. All stents were inserted into a common bile duct through a duodenal papilla following small dilatation. Aftersurgical evaluation of abdominal cavities, the pigs were sacrificed to remove common bile ducts with the stents. All bile ducts were assessed by macroscopic and histopathologic examination. Results: Self-expansion was correct in all cases. Neither bile duct obstruction nor postsurgical complications were observed. Macroscopic evaluation indicated lightening of the stent color in 2 wk, a partial disintegration in 8 wk, and a complete absorption in 13 and 20 wk.
Název v anglickém jazyce
Self-expandable biodegradable biliary stents in porcine model
Popis výsledku anglicky
Background: Treatment or prevention of a benign biliary tree stricture is an unresolved problem. A novel self-expandable biodegradable polydioxanon biliary stent in a porcine model was studied. Materials and methods: This new stent was used in 23 pigs. Feasibility and safety of surgical stenting, time of biodegradation, and histologic reaction in 2, 8, 13, and 20 wk of a follow-up were studied. All stents were inserted into a common bile duct through a duodenal papilla following small dilatation. Aftersurgical evaluation of abdominal cavities, the pigs were sacrificed to remove common bile ducts with the stents. All bile ducts were assessed by macroscopic and histopathologic examination. Results: Self-expansion was correct in all cases. Neither bile duct obstruction nor postsurgical complications were observed. Macroscopic evaluation indicated lightening of the stent color in 2 wk, a partial disintegration in 8 wk, and a complete absorption in 13 and 20 wk.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FJ - Chirurgie včetně transplantologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Surgical Research
ISSN
0022-4804
e-ISSN
—
Svazek periodika
193
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
606-612
Kód UT WoS článku
000346244300014
EID výsledku v databázi Scopus
—