Home monitoring of implantable cardioverter-defibrillators: interpretation reliability of the second-generation "IEGM Online" system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00086611" target="_blank" >RIV/00216224:14110/15:00086611 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00159816:_____/15:00063948
Výsledek na webu
<a href="http://dx.doi.org/10.1093/europace/euu349" target="_blank" >http://dx.doi.org/10.1093/europace/euu349</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/europace/euu349" target="_blank" >10.1093/europace/euu349</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Home monitoring of implantable cardioverter-defibrillators: interpretation reliability of the second-generation "IEGM Online" system
Popis výsledku v původním jazyce
Aims Intracardiac electrograms (IEGMs) are essential for the assessment of implantable cardioverter-defibrillator (ICD) function. The Biotronik Home Monitoring systems transmit an 'IEGM Online' that is shorter than the full-length programmer IEGM due totechnical constrains. The aim of this study was to evaluate the accuracy of the physician's classification of the underlying rhythm based on the second-generation IEGM Online. Methods and results In total, 1533 patients treated with single-and dual-chamber ICDs and cardiac resynchronization therapy defibrillators were enrolled at 67 investigational sites and followed for 15 months. The investigators classified the rhythm shown in IEGM Online as ventricular tachycardia, ventricular fibrillation, atrial fibrillation, other supraventricular tachyarrhythmia, oversensing due to lead failure, T-wave oversensing, or other rhythm. At the next in-office follow-up, the investigators classified independently the rhythm seen in the corresponding pr
Název v anglickém jazyce
Home monitoring of implantable cardioverter-defibrillators: interpretation reliability of the second-generation "IEGM Online" system
Popis výsledku anglicky
Aims Intracardiac electrograms (IEGMs) are essential for the assessment of implantable cardioverter-defibrillator (ICD) function. The Biotronik Home Monitoring systems transmit an 'IEGM Online' that is shorter than the full-length programmer IEGM due totechnical constrains. The aim of this study was to evaluate the accuracy of the physician's classification of the underlying rhythm based on the second-generation IEGM Online. Methods and results In total, 1533 patients treated with single-and dual-chamber ICDs and cardiac resynchronization therapy defibrillators were enrolled at 67 investigational sites and followed for 15 months. The investigators classified the rhythm shown in IEGM Online as ventricular tachycardia, ventricular fibrillation, atrial fibrillation, other supraventricular tachyarrhythmia, oversensing due to lead failure, T-wave oversensing, or other rhythm. At the next in-office follow-up, the investigators classified independently the rhythm seen in the corresponding pr
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Europace
ISSN
1099-5129
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
584-590
Kód UT WoS článku
000354445400015
EID výsledku v databázi Scopus
—