EIGHT - FIGURE PLATE SYSTEM FOR CORRECTION OF ANGULAR DEFORMITIES OF LOWER LIMBS IN CHILDREN. INITIAL RESULTS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F16%3A00099215" target="_blank" >RIV/00216224:14110/16:00099215 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EIGHT - FIGURE PLATE SYSTEM FOR CORRECTION OF ANGULAR DEFORMITIES OF LOWER LIMBS IN CHILDREN. INITIAL RESULTS
Popis výsledku v původním jazyce
The aim of the study is to present results of our experience with 8-figure plate system for treatment of angular deformities of lower limbs. 19 patients underwent surgery using 8-plates for correction of angular deformities with diagnosis of genu valgum or genua valga. Clinical evaluation and X-ray documentation was performed on regular basis including clinical measurements of intermal-leolar distance (IMD) and radiological assessment of lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA). Average preoperative measurements were IMD=15.8 cm, LDFA=81° and MPTA=97°. At the time of hardware removal, average LDFA raised to 89° (87-92) and average MPTA lowered to 88° (86-89). The hardware was removed in 9.1 months after surgery in average. No complications were observed. 8-plates appeared to be optimal treatment option for correction of angular lower limb deformities showing advantages over the Blount's staples. It also brings the possibility to intervene in children younger than 10 years of age.
Název v anglickém jazyce
EIGHT - FIGURE PLATE SYSTEM FOR CORRECTION OF ANGULAR DEFORMITIES OF LOWER LIMBS IN CHILDREN. INITIAL RESULTS
Popis výsledku anglicky
The aim of the study is to present results of our experience with 8-figure plate system for treatment of angular deformities of lower limbs. 19 patients underwent surgery using 8-plates for correction of angular deformities with diagnosis of genu valgum or genua valga. Clinical evaluation and X-ray documentation was performed on regular basis including clinical measurements of intermal-leolar distance (IMD) and radiological assessment of lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA). Average preoperative measurements were IMD=15.8 cm, LDFA=81° and MPTA=97°. At the time of hardware removal, average LDFA raised to 89° (87-92) and average MPTA lowered to 88° (86-89). The hardware was removed in 9.1 months after surgery in average. No complications were observed. 8-plates appeared to be optimal treatment option for correction of angular lower limb deformities showing advantages over the Blount's staples. It also brings the possibility to intervene in children younger than 10 years of age.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
30212 - Surgery
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Pohybové ústrojí
ISSN
1212-4575
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
12
Strana od-do
82-93
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—