Disparity Between Two-Dimensional Echocardiographic and Electroanatomic Left and Right Atrial Volumes in Patients Undergoing Catheter Ablation for Long-Standing Persistent Atrial Fibrillation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F17%3A00113802" target="_blank" >RIV/00216224:14110/17:00113802 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/17:10332402 RIV/00023001:_____/17:00075883 RIV/00064165:_____/17:10332402 RIV/65269705:_____/17:00074194
Výsledek na webu
<a href="http://www.biomed.cas.cz/physiolres/pdf/66/66_241.pdf" target="_blank" >http://www.biomed.cas.cz/physiolres/pdf/66/66_241.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33549/physiolres.933314" target="_blank" >10.33549/physiolres.933314</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Disparity Between Two-Dimensional Echocardiographic and Electroanatomic Left and Right Atrial Volumes in Patients Undergoing Catheter Ablation for Long-Standing Persistent Atrial Fibrillation
Popis výsledku v původním jazyce
Left atrial (LA) volume (LAV) is used for the selection of patients with atrial fibrillation (AF) to rhythm control strategies. Calculation of LAV from the LA diameters and areas by two-dimensional (2D) echocardiography may result in significant error. Accuracy of atrial volume assessment has never been studied in patients with long-standing persistent AF (LSPAF) and significant atrial remodeling. This study investigated correlation and agreement between 2D echocardiographic (Simpson method) and electroanatomic (CARTO, Biosense Webster) left and right atrial (RA) volumes (LAV(ECHO) vs. LAV(CARTO) and RAV(ECHO) vs. RAV(CARTO)) in patients undergoing catheter ablation for LSPAF. The study enrolled 173 consecutive subjects (females: 21 %, age: 59 +/- 9 years). There was only modest correlation between LAVECHO (92 +/- 31 ml) and LAV(CARTO) (178 +/- 37 ml) (R= 0.57), and RAV(ECHO) (71 +/- 29 ml) and RAV(CARTO) (173 +/- 34 ml) (R= 0.42), respectively. LAV(ECHO) and RAV(ECHO) underestimated LAV(CARTO) and RAV(CARTO) with the absolute bias (+/- 1.96 standard deviation) of -85 (-148; -22) ml and -102 (-169; -35) ml, respectively, and with the relative bias of -48 (-75; -21) % and -59 (-88; -30) %, respectively (all P<0.000001 for their mutual difference). Significant confounders of this difference were not identified. In patients with LSPAF, 2D echocardiography significantly underestimated both LA and RA volumes as compared with electroanatomic reference. This disagreement was independent of clinical, echocardiographic and mapping characteristics.
Název v anglickém jazyce
Disparity Between Two-Dimensional Echocardiographic and Electroanatomic Left and Right Atrial Volumes in Patients Undergoing Catheter Ablation for Long-Standing Persistent Atrial Fibrillation
Popis výsledku anglicky
Left atrial (LA) volume (LAV) is used for the selection of patients with atrial fibrillation (AF) to rhythm control strategies. Calculation of LAV from the LA diameters and areas by two-dimensional (2D) echocardiography may result in significant error. Accuracy of atrial volume assessment has never been studied in patients with long-standing persistent AF (LSPAF) and significant atrial remodeling. This study investigated correlation and agreement between 2D echocardiographic (Simpson method) and electroanatomic (CARTO, Biosense Webster) left and right atrial (RA) volumes (LAV(ECHO) vs. LAV(CARTO) and RAV(ECHO) vs. RAV(CARTO)) in patients undergoing catheter ablation for LSPAF. The study enrolled 173 consecutive subjects (females: 21 %, age: 59 +/- 9 years). There was only modest correlation between LAVECHO (92 +/- 31 ml) and LAV(CARTO) (178 +/- 37 ml) (R= 0.57), and RAV(ECHO) (71 +/- 29 ml) and RAV(CARTO) (173 +/- 34 ml) (R= 0.42), respectively. LAV(ECHO) and RAV(ECHO) underestimated LAV(CARTO) and RAV(CARTO) with the absolute bias (+/- 1.96 standard deviation) of -85 (-148; -22) ml and -102 (-169; -35) ml, respectively, and with the relative bias of -48 (-75; -21) % and -59 (-88; -30) %, respectively (all P<0.000001 for their mutual difference). Significant confounders of this difference were not identified. In patients with LSPAF, 2D echocardiography significantly underestimated both LA and RA volumes as compared with electroanatomic reference. This disagreement was independent of clinical, echocardiographic and mapping characteristics.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30105 - Physiology (including cytology)
Návaznosti výsledku
Projekt
<a href="/cs/project/NR9143" target="_blank" >NR9143: Klinický význam přídatných pravosíňových lézí připojených k obkružujícím a lineárním lézím v levé srdeční síni v ablační léčbě chronické fibrilace síní - prospektivní randomizovaná studie</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological research
ISSN
0862-8408
e-ISSN
—
Svazek periodika
66
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
241-249
Kód UT WoS článku
000404258800007
EID výsledku v databázi Scopus
2-s2.0-85019235935