Heavy water enhancement of fluorescence signal in reversed-phase liquid chromatography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F18%3A00102906" target="_blank" >RIV/00216224:14110/18:00102906 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jchromb.2018.05.037" target="_blank" >http://dx.doi.org/10.1016/j.jchromb.2018.05.037</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jchromb.2018.05.037" target="_blank" >10.1016/j.jchromb.2018.05.037</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Heavy water enhancement of fluorescence signal in reversed-phase liquid chromatography
Popis výsledku v původním jazyce
Liquid chromatography with fluorescence detection has been used in analyses demanding high sensitivity and selectivity. As majority systems rely on reversed-phase columns with water being the main component of the mobile phase, fluorescent compounds with emission maxima higher than 500 nm might be dynamically quenched. A simple replacement of H2O with D2O enhanced the sensitivity for selected compounds by 10–200 per cent. Affected compounds included an anti-cancer drug doxorubicin, a luminescent probe fluorescein, and naturally occurring forms of vitamin B2. Similar levels of enhancement were obtained by fluorescence spectrometry. Such simple yet effective approach may greatly improve HPLC analyses coupled to fluorescence detection.
Název v anglickém jazyce
Heavy water enhancement of fluorescence signal in reversed-phase liquid chromatography
Popis výsledku anglicky
Liquid chromatography with fluorescence detection has been used in analyses demanding high sensitivity and selectivity. As majority systems rely on reversed-phase columns with water being the main component of the mobile phase, fluorescent compounds with emission maxima higher than 500 nm might be dynamically quenched. A simple replacement of H2O with D2O enhanced the sensitivity for selected compounds by 10–200 per cent. Affected compounds included an anti-cancer drug doxorubicin, a luminescent probe fluorescein, and naturally occurring forms of vitamin B2. Similar levels of enhancement were obtained by fluorescence spectrometry. Such simple yet effective approach may greatly improve HPLC analyses coupled to fluorescence detection.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
ISSN
1570-0232
e-ISSN
1873-376X
Svazek periodika
1092
Číslo periodika v rámci svazku
AUG 15 2018
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
7-14
Kód UT WoS článku
000439403100002
EID výsledku v databázi Scopus
2-s2.0-85047786978