THE COMPARISON OF THE EFFICIENCY OF COLON CAPSULE ENDOSCOPY AND OPTICAL COLONOSCOPY IN PATIENTS WITH POSITIVE IMMUNOCHEMICAL FECAL OCCULT BLOOD TEST: MULTICENTER, PROSPECTIVE STUDY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F19%3A00108632" target="_blank" >RIV/00216224:14110/19:00108632 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61383082:_____/19:00000559
Výsledek na webu
<a href="https://www.giejournal.org/article/S0016-5107(19)30794-1/fulltext" target="_blank" >https://www.giejournal.org/article/S0016-5107(19)30794-1/fulltext</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.gie.2019.03.603" target="_blank" >10.1016/j.gie.2019.03.603</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
THE COMPARISON OF THE EFFICIENCY OF COLON CAPSULE ENDOSCOPY AND OPTICAL COLONOSCOPY IN PATIENTS WITH POSITIVE IMMUNOCHEMICAL FECAL OCCULT BLOOD TEST: MULTICENTER, PROSPECTIVE STUDY
Popis výsledku v původním jazyce
Fecal immunochemical tests (FIT) have been used as an initial test in CRC screening programs. However, majority of patients don't have advanced neoplasia on colonoscopy. Colon capsule endoscopy (CCE) has the potential to reduce the need for optical colonoscopy (OC). The main aim of the study was a negative predictive value (NPV) of the second generation of colon capsule endoscopy (CCE2) for large polyps (_> 10 mm). The secondary aims were: accuracy of detection of all polyps (polyps _> 6 mm and _> 10 mm) and cancers, the number of complications and target population acceptance of both methods (CCE2 and OC).
Název v anglickém jazyce
THE COMPARISON OF THE EFFICIENCY OF COLON CAPSULE ENDOSCOPY AND OPTICAL COLONOSCOPY IN PATIENTS WITH POSITIVE IMMUNOCHEMICAL FECAL OCCULT BLOOD TEST: MULTICENTER, PROSPECTIVE STUDY
Popis výsledku anglicky
Fecal immunochemical tests (FIT) have been used as an initial test in CRC screening programs. However, majority of patients don't have advanced neoplasia on colonoscopy. Colon capsule endoscopy (CCE) has the potential to reduce the need for optical colonoscopy (OC). The main aim of the study was a negative predictive value (NPV) of the second generation of colon capsule endoscopy (CCE2) for large polyps (_> 10 mm). The secondary aims were: accuracy of detection of all polyps (polyps _> 6 mm and _> 10 mm) and cancers, the number of complications and target population acceptance of both methods (CCE2 and OC).
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
30219 - Gastroenterology and hepatology
Návaznosti výsledku
Projekt
<a href="/cs/project/NV16-29614A" target="_blank" >NV16-29614A: Porovnání účinnosti kolonické kapslové endoskopie a optické kolonoskopie u osob s pozitivním imunochemickým testem na okultní krvácení do stolice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů