Hinged Elbow External Fixation for Severe Elbow Stiffness
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F19%3A00110216" target="_blank" >RIV/00216224:14110/19:00110216 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.ncbi.nlm.nih.gov/pubmed/31070573" target="_blank" >https://www.ncbi.nlm.nih.gov/pubmed/31070573</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hinged Elbow External Fixation for Severe Elbow Stiffness
Popis výsledku v původním jazyce
PURPOSE OF THE STUDY The elbow is a highly constrained synovial hinge joint that frequently becomes stiff after injury. Grade 4 elbow stiffness (ankylosis) is a strongly limiting factor in the patient s daily activities and is difficult to treat. Hinged external fixation of the elbow provides the advantages of static fixation with the benefits of continued motion of the joint. The goal of our study was to assess the improvement in the range of motion of the elbow after surgical arthrolysis using a posterior extensile approach to the joint with or without using external fixation. MATERIAL AND METHODS Sixteen patients aged between 19 and 46 years with grade 4 elbow stiffness were operated on. The stiffness was caused by the following pathologies: 7 elbow dislocations, 3 radial head fractures, 4 distal humeral fractures, 2 fracture-dislocations. The average range of motion before surgery was 14 (range 0-20). The average interval between primary injury and arthrolysis was 24 months (9-60 months). The clinical assessment before and after the surgery was based on the Mayo Elbow Performance Score (MEPS). The average follow-up was 30 months (18-50 months). Arthrolysis was completed by application of an external fixator in eight patients. RESULTS A few common complications were observed, including the injury to adjacent neurovascular structures (two cases of temporary irritation of the ulnar nerve, one case of temporary irritation of the radial nerve) and three cases of pin-track infections. None of the patients showed elbow instability. In Group I, in which external fixation was used, the average MEP score increased from 51 points (range, 30 to 70) to 78 points (range, 55 to 90). The average range of motion at the final follow-up was 93 (range, 75-135). In Group II, in which no external fixation was used, the average MEP score increased from 53 points (range, 35 to 70) to 76 points (range, 55 to 85). The gain in flexion-extension was 88 (range, 65-135). The final improvement in the range of motion depended mostly on the severity of preoperative stiffness and subsequent surgery. DISCUSSION The surgical arthrolysis of the ankylosed elbow is not a procedure commonly performed by majority of hospitals. A precise surgical technique is a prerequisite for success of the procedure. The type of injury did not seem to influence the final result. Articular external fixation potentially provides stability while permitting the movement. CONCLUSIONS Open arthrolysis of a severe elbow contracture results in a substantial gain in motion (with or without using elbow external fixation) and gives reliable long-lasting results. The minimal improvement in motion provided by the hinge fixator does not justify the associated increase in the risk of complications.
Název v anglickém jazyce
Hinged Elbow External Fixation for Severe Elbow Stiffness
Popis výsledku anglicky
PURPOSE OF THE STUDY The elbow is a highly constrained synovial hinge joint that frequently becomes stiff after injury. Grade 4 elbow stiffness (ankylosis) is a strongly limiting factor in the patient s daily activities and is difficult to treat. Hinged external fixation of the elbow provides the advantages of static fixation with the benefits of continued motion of the joint. The goal of our study was to assess the improvement in the range of motion of the elbow after surgical arthrolysis using a posterior extensile approach to the joint with or without using external fixation. MATERIAL AND METHODS Sixteen patients aged between 19 and 46 years with grade 4 elbow stiffness were operated on. The stiffness was caused by the following pathologies: 7 elbow dislocations, 3 radial head fractures, 4 distal humeral fractures, 2 fracture-dislocations. The average range of motion before surgery was 14 (range 0-20). The average interval between primary injury and arthrolysis was 24 months (9-60 months). The clinical assessment before and after the surgery was based on the Mayo Elbow Performance Score (MEPS). The average follow-up was 30 months (18-50 months). Arthrolysis was completed by application of an external fixator in eight patients. RESULTS A few common complications were observed, including the injury to adjacent neurovascular structures (two cases of temporary irritation of the ulnar nerve, one case of temporary irritation of the radial nerve) and three cases of pin-track infections. None of the patients showed elbow instability. In Group I, in which external fixation was used, the average MEP score increased from 51 points (range, 30 to 70) to 78 points (range, 55 to 90). The average range of motion at the final follow-up was 93 (range, 75-135). In Group II, in which no external fixation was used, the average MEP score increased from 53 points (range, 35 to 70) to 76 points (range, 55 to 85). The gain in flexion-extension was 88 (range, 65-135). The final improvement in the range of motion depended mostly on the severity of preoperative stiffness and subsequent surgery. DISCUSSION The surgical arthrolysis of the ankylosed elbow is not a procedure commonly performed by majority of hospitals. A precise surgical technique is a prerequisite for success of the procedure. The type of injury did not seem to influence the final result. Articular external fixation potentially provides stability while permitting the movement. CONCLUSIONS Open arthrolysis of a severe elbow contracture results in a substantial gain in motion (with or without using elbow external fixation) and gives reliable long-lasting results. The minimal improvement in motion provided by the hinge fixator does not justify the associated increase in the risk of complications.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30211 - Orthopaedics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta chirurgiae orthopaedicae et traumatologiae čechoslovaca
ISSN
0001-5415
e-ISSN
—
Svazek periodika
86
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
136-140
Kód UT WoS článku
000466619700007
EID výsledku v databázi Scopus
2-s2.0-85065795015