Medical device-related pressure injury prevention related to fixation of nutritional and derivative probes: a best practice implementation project
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F22%3A00126874" target="_blank" >RIV/00216224:14110/22:00126874 - isvavai.cz</a>
Výsledek na webu
<a href="https://journals.lww.com/ijebh/Abstract/2022/08001/Medical_device_related_pressure_injury_prevention.5.aspx" target="_blank" >https://journals.lww.com/ijebh/Abstract/2022/08001/Medical_device_related_pressure_injury_prevention.5.aspx</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/XEB.0000000000000318" target="_blank" >10.1097/XEB.0000000000000318</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Medical device-related pressure injury prevention related to fixation of nutritional and derivative probes: a best practice implementation project
Popis výsledku v původním jazyce
Objectives: The main objective was to improve the provision of clinical care in pressure injury prevention related to the use of medical devices focused on nasogastric probes. Introduction: The insertion of nasogastric probes could lead to the formation of medical device-related pressure injuries (MDRPI). The risk increases with the length of the probe insertion and is higher in patients in intensive care. MDRPI prevention is mostly based on appropriate skin and mucosa membrane and tissue monitoring and positioning of the medical devices. Methods: The project has been conducted based on JBI Implementation approach for promoting change in healthcare practice. A baseline audit on MDRPI prevention was undertaken and involved 21 nurses and 12 patients using a questionnaire for nurses and a record sheet for patient's monitoring. The intervention included education, clinical practice training, consultation, and other strategies. A follow-up audit was undertaken, including all original participants. Results data on changes in compliance were measured using descriptive statistics embedded in JBI-PACES in the form of percentage changes from baseline. Results: There were significantly improved outcomes across all best practice criteria. The level of knowledge of nurses increased. Skin barrier creams and mass-supplied fixation are now used to prevent skin injuries on the nose. The new monitoring and documentation is more accurate and in line with evidence-based practice. Conclusion: Overall, the project achieved an improvement in evidence-based practice in the prevention of MDRPI in patients with nasogastric probes based on nurses' increased level of knowledge and usage of appropriate preventative measures.
Název v anglickém jazyce
Medical device-related pressure injury prevention related to fixation of nutritional and derivative probes: a best practice implementation project
Popis výsledku anglicky
Objectives: The main objective was to improve the provision of clinical care in pressure injury prevention related to the use of medical devices focused on nasogastric probes. Introduction: The insertion of nasogastric probes could lead to the formation of medical device-related pressure injuries (MDRPI). The risk increases with the length of the probe insertion and is higher in patients in intensive care. MDRPI prevention is mostly based on appropriate skin and mucosa membrane and tissue monitoring and positioning of the medical devices. Methods: The project has been conducted based on JBI Implementation approach for promoting change in healthcare practice. A baseline audit on MDRPI prevention was undertaken and involved 21 nurses and 12 patients using a questionnaire for nurses and a record sheet for patient's monitoring. The intervention included education, clinical practice training, consultation, and other strategies. A follow-up audit was undertaken, including all original participants. Results data on changes in compliance were measured using descriptive statistics embedded in JBI-PACES in the form of percentage changes from baseline. Results: There were significantly improved outcomes across all best practice criteria. The level of knowledge of nurses increased. Skin barrier creams and mass-supplied fixation are now used to prevent skin injuries on the nose. The new monitoring and documentation is more accurate and in line with evidence-based practice. Conclusion: Overall, the project achieved an improvement in evidence-based practice in the prevention of MDRPI in patients with nasogastric probes based on nurses' increased level of knowledge and usage of appropriate preventative measures.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30218 - General and internal medicine
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JBI EVIDENCE IMPLEMENTATION
ISSN
2691-3321
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
Supplement1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
„S32“-„S40“
Kód UT WoS článku
000858607100005
EID výsledku v databázi Scopus
2-s2.0-85141682270