Nasogastric tube care and flushing in a Portuguese general medicine ward: a best practice implementation project
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F22%3A00126987" target="_blank" >RIV/00216224:14110/22:00126987 - isvavai.cz</a>
Výsledek na webu
<a href="https://journals.lww.com/ijebh/Abstract/2022/08001/Nasogastric_tube_care_and_flushing_in_a_Portuguese.10.aspx" target="_blank" >https://journals.lww.com/ijebh/Abstract/2022/08001/Nasogastric_tube_care_and_flushing_in_a_Portuguese.10.aspx</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/XEB.0000000000000328" target="_blank" >10.1097/XEB.0000000000000328</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nasogastric tube care and flushing in a Portuguese general medicine ward: a best practice implementation project
Popis výsledku v původním jazyce
Objectives: To implement evidence-based practice related to care and flushing of nasogastric tubes inserted for feeding, in a general medicine ward. Introduction: Nasogastric tube feeding is a widely used nutritional support form. Although performed by qualified professionals, it is not a harm-free intervention. Progression to the trachea during initial insertion, aspiration of gastric contents, improper position for patient feeding, and/or a blocked tube are examples of problems that can occur. Methods: The project used JBI's methodological approach of the Clinical Evidence System and Getting Research into Practice audit and feedback tool. A baseline audit focused on nursing procedures related to the maintenance of nasogastric tube feeding, based on 14 criteria informed by the JBI evidence summaries, was performed for a month. Education sessions and other engagement strategies and resources were used to increase nasogastric tube maintenance. This best-practice implementation was conducted in Portugal, between January 2020 and April 2021, in a 33-bed general medicine ward with a staff of 30 registered nurses. Results: Different samples, for each audited procedure, were obtained from a universe of 25 nurses and 14 episodes of patients with nasogastric tube in baseline and 10 in follow-up audit. At baseline, compliance with the criteria ranged from 0 to 88%. Ten of the 14 criteria were below 50%. The follow-up audit showed significant improvement in all compliance criteria (ranging from 44.4 to 100%). Criteria 1 and 2, which were aimed at preventing adverse consequences related to wrong placement or displacement of the nasogastric tube, showed a high postimplementation compliance level (89.3 and 90%). Conclusion: With an integrated plan incorporating interventions, strategies, and resources, tailored for this context, we improved nurses' knowledge of nasogastric tube maintenance and achieved significantly increased compliance with nasogastric tube care best-practice. We suggest maintaining current strategies, and reinforcing clinical supervision and regular assessment.
Název v anglickém jazyce
Nasogastric tube care and flushing in a Portuguese general medicine ward: a best practice implementation project
Popis výsledku anglicky
Objectives: To implement evidence-based practice related to care and flushing of nasogastric tubes inserted for feeding, in a general medicine ward. Introduction: Nasogastric tube feeding is a widely used nutritional support form. Although performed by qualified professionals, it is not a harm-free intervention. Progression to the trachea during initial insertion, aspiration of gastric contents, improper position for patient feeding, and/or a blocked tube are examples of problems that can occur. Methods: The project used JBI's methodological approach of the Clinical Evidence System and Getting Research into Practice audit and feedback tool. A baseline audit focused on nursing procedures related to the maintenance of nasogastric tube feeding, based on 14 criteria informed by the JBI evidence summaries, was performed for a month. Education sessions and other engagement strategies and resources were used to increase nasogastric tube maintenance. This best-practice implementation was conducted in Portugal, between January 2020 and April 2021, in a 33-bed general medicine ward with a staff of 30 registered nurses. Results: Different samples, for each audited procedure, were obtained from a universe of 25 nurses and 14 episodes of patients with nasogastric tube in baseline and 10 in follow-up audit. At baseline, compliance with the criteria ranged from 0 to 88%. Ten of the 14 criteria were below 50%. The follow-up audit showed significant improvement in all compliance criteria (ranging from 44.4 to 100%). Criteria 1 and 2, which were aimed at preventing adverse consequences related to wrong placement or displacement of the nasogastric tube, showed a high postimplementation compliance level (89.3 and 90%). Conclusion: With an integrated plan incorporating interventions, strategies, and resources, tailored for this context, we improved nurses' knowledge of nasogastric tube maintenance and achieved significantly increased compliance with nasogastric tube care best-practice. We suggest maintaining current strategies, and reinforcing clinical supervision and regular assessment.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30218 - General and internal medicine
Návaznosti výsledku
Projekt
<a href="/cs/project/LTC20031" target="_blank" >LTC20031: Towards an International Network for Evidence-based Research in Clinical Health Research in the Czech Republic</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JBI EVIDENCE IMPLEMENTATION
ISSN
2691-3321
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
Supplement 1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
„S76“-„S87“
Kód UT WoS článku
000858607100010
EID výsledku v databázi Scopus
2-s2.0-85141678070