Application of Elimination Voltammetry to the Electroanalysis of an Adsorbed Substance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F00%3A00003067" target="_blank" >RIV/00216224:14310/00:00003067 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of Elimination Voltammetry to the Electroanalysis of an Adsorbed Substance
Popis výsledku v původním jazyce
In the elimination voltammetry with a linear scan rate (EVLS), elimination of the selected particular currents from the linear scan voltammetry results is achieved by an elimination function formed by a linear combination of the total currents measured at different scan rates.Theoretical curves of an irreversible current with adsorbed substance being electroactive were calculated for three elimination functions: A - the function eliminating Ik and Ic and conserving Ir , B - the function eliminating Ic and Ir , conserving Ik , and C - the function eliminating Ir and Ik and conserving Ic, where Ic , Ir , and Ik are the charging current, the reversible diffusion current, and the kinetic current, respectively. A larger difference between diffusion and adsorption was exhibited by the elimination function A. It provides a substantial increase in resolution and sensitivity as compared to the linear scan voltammetry current peak and clearly marks the adsorption.
Název v anglickém jazyce
Application of Elimination Voltammetry to the Electroanalysis of an Adsorbed Substance
Popis výsledku anglicky
In the elimination voltammetry with a linear scan rate (EVLS), elimination of the selected particular currents from the linear scan voltammetry results is achieved by an elimination function formed by a linear combination of the total currents measured at different scan rates.Theoretical curves of an irreversible current with adsorbed substance being electroactive were calculated for three elimination functions: A - the function eliminating Ik and Ic and conserving Ir , B - the function eliminating Ic and Ir , conserving Ik , and C - the function eliminating Ir and Ik and conserving Ic, where Ic , Ir , and Ik are the charging current, the reversible diffusion current, and the kinetic current, respectively. A larger difference between diffusion and adsorption was exhibited by the elimination function A. It provides a substantial increase in resolution and sensitivity as compared to the linear scan voltammetry current peak and clearly marks the adsorption.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GV204%2F97%2FK084" target="_blank" >GV204/97/K084: Elektrody modifikované nukleovými kyselinami a bílkovinami. Nové nástroje v biochemickém a biomedicínském výzkumu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2000
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Electroanalysis ESEAC 2000 SEAC
ISBN
3-89336-261-4
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
—
Název nakladatele
Rheinische-Friedrich-Wilhelms-Universitaet Bonn
Místo vydání
Bonn
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—