Application of Elimination Methods in Electrochemical Study of DNA
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F00%3A00003961" target="_blank" >RIV/00216224:14310/00:00003961 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of Elimination Methods in Electrochemical Study of DNA
Popis výsledku v původním jazyce
Non-conventional electrochemical methods, such as elimination polarography (EP) and elimination voltammetry with linear scan (EVLS) provide the elimination of selected particular currents, forming the measured total current. The most frequently eliminated particular currents are the charging current (Ic), the diffusion current (Id), and the kinetic current (Ik). While the LSV signal of single-stranded DNA at low concentration gives a slight hint in the cathodic process of adenine and cytosine residues,the elimination of Ic and Ik provides quite a clear signal in the form of the peak-counterpeak, which enables the determination of DNA at concentrations below microgram per millilitre. The results received by the adsorptive stripping voltammetry in the mode of linear scan (LSV), square-wave (SWV) and elimination with linear scan (EVLS) are compared and discussed.
Název v anglickém jazyce
Application of Elimination Methods in Electrochemical Study of DNA
Popis výsledku anglicky
Non-conventional electrochemical methods, such as elimination polarography (EP) and elimination voltammetry with linear scan (EVLS) provide the elimination of selected particular currents, forming the measured total current. The most frequently eliminated particular currents are the charging current (Ic), the diffusion current (Id), and the kinetic current (Ik). While the LSV signal of single-stranded DNA at low concentration gives a slight hint in the cathodic process of adenine and cytosine residues,the elimination of Ic and Ik provides quite a clear signal in the form of the peak-counterpeak, which enables the determination of DNA at concentrations below microgram per millilitre. The results received by the adsorptive stripping voltammetry in the mode of linear scan (LSV), square-wave (SWV) and elimination with linear scan (EVLS) are compared and discussed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GV204%2F97%2FK084" target="_blank" >GV204/97/K084: Elektrody modifikované nukleovými kyselinami a bílkovinami. Nové nástroje v biochemickém a biomedicínském výzkumu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2000
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Book of Abstracts - DNA Structure and Interactions
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
—
Název nakladatele
Institute of Biophysics, Academy of Sciences, Czech Republic
Místo vydání
Brno, Czech Republic
Místo konání akce
Brno, Czech Republic
Datum konání akce
1. 1. 2000
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—