Development of a disposable electrochemical immunosensor for detection of the herbicide acetochlor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F03%3A00008148" target="_blank" >RIV/00216224:14310/03:00008148 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of a disposable electrochemical immunosensor for detection of the herbicide acetochlor
Popis výsledku v původním jazyce
The electrochemical immunosensor for the detection of the herbicide acetochlor was developed. Initially, the feasibility of the immunosensor was verified using the standard ELISA technique employing the competitive assay format with immobilized acetochlor. The assay principle of the disposable immunochemical biosensor was similar. The screen-printed electrode system served as the transducer, acetochlor was covalently immobilized on the surface of the gold working electrode activated with a self-assembled monolayer of cystamine. Acetochlor was linked to this layer through S-acetylmercaptosuccinic anhydride (AMSA). A limited amount of anti-acetochlor polyclonal rabbit antibody in solution competed with the analyzed acetochlor and the secondary goat anti-rabbit antibody labeled with peroxidase was chosen for detection. The amperometric measurement of peroxidase activity was carried out using 5?aminosalicylic acid (ASA) and hydrogen peroxide as substrates. Successful regeneration of the se
Název v anglickém jazyce
Development of a disposable electrochemical immunosensor for detection of the herbicide acetochlor
Popis výsledku anglicky
The electrochemical immunosensor for the detection of the herbicide acetochlor was developed. Initially, the feasibility of the immunosensor was verified using the standard ELISA technique employing the competitive assay format with immobilized acetochlor. The assay principle of the disposable immunochemical biosensor was similar. The screen-printed electrode system served as the transducer, acetochlor was covalently immobilized on the surface of the gold working electrode activated with a self-assembled monolayer of cystamine. Acetochlor was linked to this layer through S-acetylmercaptosuccinic anhydride (AMSA). A limited amount of anti-acetochlor polyclonal rabbit antibody in solution competed with the analyzed acetochlor and the secondary goat anti-rabbit antibody labeled with peroxidase was chosen for detection. The amperometric measurement of peroxidase activity was carried out using 5?aminosalicylic acid (ASA) and hydrogen peroxide as substrates. Successful regeneration of the se
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA525%2F97%2F0924" target="_blank" >GA525/97/0924: Stopová analýza toxických PCB a pesticidů s využitím detekčních a separačních metod založených na protilátkové specifitě</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Environmental and Analytical Chemistry
ISSN
0306-7319
e-ISSN
—
Svazek periodika
83
Číslo periodika v rámci svazku
7-8
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
609-620
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—