Stanovení isoflavon v sojových bobech a v lidské moi za použití HPLC s elektrochemickou detekcí
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F04%3A00011226" target="_blank" >RIV/00216224:14310/04:00011226 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62156489:43210/04:00000330
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of isoflavones in soybean food and human urine using liquid chromatography with electrochemical detection
Popis výsledku v původním jazyce
A highly sensitive high-performance liquid chromatographic method with electrochemical detection (HPLC-ED) was developed for the determination of isoflavones. Electrochemical behaviour of daidzein and genistein was studied on carbon paste electrode (CPE)by adsorptive transfer stripping square wave voltammetry. The obtained electrochemical results were used for the development of HPLC-ED method. Furthermore, isoflavones were separated on an Atlantis dC18 column using a mobile phase consisting of acetonitrile (solvent A) and 0.15M acetate buffer of pH 5.5 (solvent B) at a flow rate 0.4 mL/min. A linear gradient profile (solvent B) was at 02 min 87%; 22 min 60%; 27 min 50%; 31 min 45%; 47 min 87%. Full scan of multi-channel coulometric detection was tested and optimal potential at 450mV was chosen for our purposes. Calibration curves were linear (daidzein R2 = 0.9993 and genistein R2 = 0.9987). The detection limit for daidzein/genistein was 480/394 pg/mL (1.8/1.5 nM) and per column 2.4/1
Název v anglickém jazyce
Determination of isoflavones in soybean food and human urine using liquid chromatography with electrochemical detection
Popis výsledku anglicky
A highly sensitive high-performance liquid chromatographic method with electrochemical detection (HPLC-ED) was developed for the determination of isoflavones. Electrochemical behaviour of daidzein and genistein was studied on carbon paste electrode (CPE)by adsorptive transfer stripping square wave voltammetry. The obtained electrochemical results were used for the development of HPLC-ED method. Furthermore, isoflavones were separated on an Atlantis dC18 column using a mobile phase consisting of acetonitrile (solvent A) and 0.15M acetate buffer of pH 5.5 (solvent B) at a flow rate 0.4 mL/min. A linear gradient profile (solvent B) was at 02 min 87%; 22 min 60%; 27 min 50%; 31 min 45%; 47 min 87%. Full scan of multi-channel coulometric detection was tested and optimal potential at 450mV was chosen for our purposes. Calibration curves were linear (daidzein R2 = 0.9993 and genistein R2 = 0.9987). The detection limit for daidzein/genistein was 480/394 pg/mL (1.8/1.5 nM) and per column 2.4/1
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography B
ISSN
1570-0232
e-ISSN
—
Svazek periodika
806
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
11
Strana od-do
101-111
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—