Piezoelektrický imunosensor pro detekci Franciselly tularensis použitím imunoglobulinu M v limitním ředění
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F05%3A00013671" target="_blank" >RIV/00216224:14310/05:00013671 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00000493:G41__/05:25152
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Piezoelectric immunosensor for Francisella tularensis detection using immunoglobulin M in a limiting dilution
Popis výsledku v původním jazyce
Francisella tularensis is a pathogenic bacterium causing the serious disease tularemia and is potentially considered as a bioweapon agent. The piezoelectric immunosensor for F. tularensis (Ft) assay was developed using the quartz crystal microbalance (QCM) with covalently immobilized Ft antigen. Samples containing the bacterium were preincubated with a highly diluted anti-Ft IgM, and the mixture was injected to the flow cell containing the immunosensor. IgM alone as well as Ft cells alone were not giving any response, and therefore, it is assumed that the sensor responded to the IgM(x)-Ft(y) complex formed during the preincubation step. The effects of pH, time of preincubation, and IgM concentration were tested. This rapid method allowed us to detect 5(.) 10(6) Ft cells/mL. RSD of measurements was near 1%. The total time of one analysis was 35 min, and one sensor was used for more than 30 times without losing sensitivity.
Název v anglickém jazyce
Piezoelectric immunosensor for Francisella tularensis detection using immunoglobulin M in a limiting dilution
Popis výsledku anglicky
Francisella tularensis is a pathogenic bacterium causing the serious disease tularemia and is potentially considered as a bioweapon agent. The piezoelectric immunosensor for F. tularensis (Ft) assay was developed using the quartz crystal microbalance (QCM) with covalently immobilized Ft antigen. Samples containing the bacterium were preincubated with a highly diluted anti-Ft IgM, and the mixture was injected to the flow cell containing the immunosensor. IgM alone as well as Ft cells alone were not giving any response, and therefore, it is assumed that the sensor responded to the IgM(x)-Ft(y) complex formed during the preincubation step. The effects of pH, time of preincubation, and IgM concentration were tested. This rapid method allowed us to detect 5(.) 10(6) Ft cells/mL. RSD of measurements was near 1%. The total time of one analysis was 35 min, and one sensor was used for more than 30 times without losing sensitivity.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OBVTUO2003001" target="_blank" >OBVTUO2003001: PROTILÁTKY 2 - Imunosenzory bojových chemických látek a bojových biologických prostředků</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Letters
ISSN
0003-2719
e-ISSN
—
Svazek periodika
38
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
12
Strana od-do
411-422
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—