Elektrochemický imunosensor pro detekci Francisella tularensis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F05%3A00015144" target="_blank" >RIV/00216224:14310/05:00015144 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00000493:G41__/05:#0000032
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical immunosensor for detection of Francisella tularensis
Popis výsledku v původním jazyce
The immunosensor for rapid and sensitive detection of Francisella tularensis (Ft) was developed using screen-printed sensors with multiple (4) Au working electrodes. The sensing zones were modified with a biolayer of anti-Ft polyclonal antibody attachedthrough the covalently immobilized Protein A. The sandwich assay format was employed with anti-Ft IgG-peroxidase conjugate as tracer. For electrochemical measurements, an automated portable detector was developed; it consisted of a digitally controlled potentiostat and four embedded miniperistaltic pumps. The flow-through measurement involved sequential incubations with sample (10 min), tracer (10 min) and substrate mixture (iodide and hydrogen peroxide). The enzymatically-produced iodine was detected electrochemically at - 50 mV. The limit of detection was 100 Ft cells/ml; the response was significantly higher (3x) when using the living cells compared to the heat inactivated ones.
Název v anglickém jazyce
Electrochemical immunosensor for detection of Francisella tularensis
Popis výsledku anglicky
The immunosensor for rapid and sensitive detection of Francisella tularensis (Ft) was developed using screen-printed sensors with multiple (4) Au working electrodes. The sensing zones were modified with a biolayer of anti-Ft polyclonal antibody attachedthrough the covalently immobilized Protein A. The sandwich assay format was employed with anti-Ft IgG-peroxidase conjugate as tracer. For electrochemical measurements, an automated portable detector was developed; it consisted of a digitally controlled potentiostat and four embedded miniperistaltic pumps. The flow-through measurement involved sequential incubations with sample (10 min), tracer (10 min) and substrate mixture (iodide and hydrogen peroxide). The enzymatically-produced iodine was detected electrochemically at - 50 mV. The limit of detection was 100 Ft cells/ml; the response was significantly higher (3x) when using the living cells compared to the heat inactivated ones.
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OBVTUO2003001" target="_blank" >OBVTUO2003001: PROTILÁTKY 2 - Imunosenzory bojových chemických látek a bojových biologických prostředků</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Defense against bioterror
ISBN
1-4020-3385-0
Počet stran výsledku
12
Strana od-do
221-232
Počet stran knihy
—
Název nakladatele
Springer
Místo vydání
Dordrecht, The Netherlands
Kód UT WoS kapitoly
—