Electrochemical Biosensor for Detection of Bioagents
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F11%3A00055984" target="_blank" >RIV/00216224:14310/11:00055984 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00000493:G41__/11:#0000386
Výsledek na webu
<a href="http://www.electrochemsci.org/papers/vol6/6125968.pdf" target="_blank" >http://www.electrochemsci.org/papers/vol6/6125968.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical Biosensor for Detection of Bioagents
Popis výsledku v původním jazyce
Simple and rapid detection and identification of dangerous bioagents is important for preventing illness or even death of people due to infectious diseases and bioterrorist threats. Electrochemical detection has a large potential for development of portable instrumentation suitable for analysis in field and especially combination with specificity of immunoassays seems promising. Initially, the construction of the immunosensing layer was realised and the effect of Au nanoparticles on the response of peroxidase was studied. An amperometric immunosensor was developed using screen-printed transducer, it employed specific capture of microbes in the sensing area by formation of an immunocomplex and its subsequent labelling using the tracer - antibody conjugated to peroxidase. The obtained sandwich electrochemical immunoassay was applied for the model microbial cells of B. subtilis. The total time of analysis was 20 min and the detection of cells below 104 CFU/ml was feasible.
Název v anglickém jazyce
Electrochemical Biosensor for Detection of Bioagents
Popis výsledku anglicky
Simple and rapid detection and identification of dangerous bioagents is important for preventing illness or even death of people due to infectious diseases and bioterrorist threats. Electrochemical detection has a large potential for development of portable instrumentation suitable for analysis in field and especially combination with specificity of immunoassays seems promising. Initially, the construction of the immunosensing layer was realised and the effect of Au nanoparticles on the response of peroxidase was studied. An amperometric immunosensor was developed using screen-printed transducer, it employed specific capture of microbes in the sensing area by formation of an immunocomplex and its subsequent labelling using the tracer - antibody conjugated to peroxidase. The obtained sandwich electrochemical immunoassay was applied for the model microbial cells of B. subtilis. The total time of analysis was 20 min and the detection of cells below 104 CFU/ml was feasible.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Electrochemical Science
ISSN
1452-3981
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
12
Strana od-do
5968-5979
Kód UT WoS článku
000297571400002
EID výsledku v databázi Scopus
—