Biosensor pro detekci sacharidů a glykovaného hemoglobinu na bázi křemenných krystalů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F05%3A00013672" target="_blank" >RIV/00216224:14310/05:00013672 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quartz crystal biosensor for detection of sugars and glycated hemoglobin
Popis výsledku v původním jazyce
3-Aminophenylboronic acid (APBA) was used for construction of affinity mass sensors for determination of saccharides and glycated hemoglobin using complexation reaction with diol groups. Two approaches were tested for the bioligand layer fabrication-incorporation of APBA inside a thicker matrix and immobilization as a self-assembled monolayer, respectively. The direct affinity sensor with APBA embeded in the structure of glutaraldehyde-crosslinked bovine serum albumine provided linear response to mono-and dissacharides in the range from 0.1 to 15.0 mg/ml. This biosensor was also used for kinetic analysis of the interaction of boronic acid with diols; the values of association and dissociation constants were determined. The sensors with a monolayer ofboronic groups were better suited for binding of glycated hemoglobin, probably due to improved steric access to the ligand.
Název v anglickém jazyce
Quartz crystal biosensor for detection of sugars and glycated hemoglobin
Popis výsledku anglicky
3-Aminophenylboronic acid (APBA) was used for construction of affinity mass sensors for determination of saccharides and glycated hemoglobin using complexation reaction with diol groups. Two approaches were tested for the bioligand layer fabrication-incorporation of APBA inside a thicker matrix and immobilization as a self-assembled monolayer, respectively. The direct affinity sensor with APBA embeded in the structure of glutaraldehyde-crosslinked bovine serum albumine provided linear response to mono-and dissacharides in the range from 0.1 to 15.0 mg/ml. This biosensor was also used for kinetic analysis of the interaction of boronic acid with diols; the values of association and dissociation constants were determined. The sensors with a monolayer ofboronic groups were better suited for binding of glycated hemoglobin, probably due to improved steric access to the ligand.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
—
Svazek periodika
530
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
10
Strana od-do
75-84
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—