Kapilární zónová elektroforéza proteinů a neuroprotektivních peptidů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F05%3A00025072" target="_blank" >RIV/00216224:14310/05:00025072 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Capillary zone electrophoresis of proteins and neuroprotective peptides
Popis výsledku v původním jazyce
Biocompatibility of inner surface of capillaries in CE is critical for separation and detection of proteins and peptides. The problems come from adsorption of the peptides (proteins) on the surface because biomolecules are sensitive to changes in ionic strength, pH, and/or temperature of the electrolyte, etc. Therefore, modification of the fused silica capillary surface is often necessary. Procedures for capillary coating described in literature are usually complicated and time consuming. We optimized three types of relatively simple coating procedures suitable for protein and peptides separation: a/ polyethyleneimine (PEI), b/ 3-glycidoxypropyltrimethoxysilane (GPTMS), c/ 3-aminopropyltriethoxysilane (APS). Composition, concentration and pH of severalbackground electrolyte were tested, namely citrate, phosphate, aminocaproate and TRIS. The capillary surface was characterized by determination of the electroosmotic flow (EOF). The conditions were optimized by running a standard mixture
Název v anglickém jazyce
Capillary zone electrophoresis of proteins and neuroprotective peptides
Popis výsledku anglicky
Biocompatibility of inner surface of capillaries in CE is critical for separation and detection of proteins and peptides. The problems come from adsorption of the peptides (proteins) on the surface because biomolecules are sensitive to changes in ionic strength, pH, and/or temperature of the electrolyte, etc. Therefore, modification of the fused silica capillary surface is often necessary. Procedures for capillary coating described in literature are usually complicated and time consuming. We optimized three types of relatively simple coating procedures suitable for protein and peptides separation: a/ polyethyleneimine (PEI), b/ 3-glycidoxypropyltrimethoxysilane (GPTMS), c/ 3-aminopropyltriethoxysilane (APS). Composition, concentration and pH of severalbackground electrolyte were tested, namely citrate, phosphate, aminocaproate and TRIS. The capillary surface was characterized by determination of the electroosmotic flow (EOF). The conditions were optimized by running a standard mixture
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA305%2F03%2F1100" target="_blank" >GA305/03/1100: Syntéza a studium neuroprotektivních peptidů odvozených od humaninu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Third International and Twenty-Eighth European Peptide Symposium. Peptides 2004.
ISBN
965-90833-0-0
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
Kenes International
Místo vydání
Geneva, Switzerland
Místo konání akce
Praha
Datum konání akce
1. 1. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—