Elektrochemický biosenzor cisplatiny
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F06%3A00016155" target="_blank" >RIV/00216224:14310/06:00016155 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62156489:43210/06:00103421
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Cisplatin electrochemical biosensor
Popis výsledku v původním jazyce
Platinum complexes play an important role in the chemotherapy of various tumour diseases. The aim of this paper was to investigate if a metallothionein (MT) modified hanging mercury drop electrode can be applied as a cisplatin electrochemical biosensor.The modification of the mercury electrode surface by MT and the determination of cisplatin were performed by adsorptive transfer stripping technique and differential pulse voltammetry. The detection limit (3 S/N) of cisplatin ([Pt-II(NH3)(2)Cl-2](0)) calculated from the decrease of CdT peak was about 2.5 pmol in 5 mu l (0.5 mu M) at the interaction time of 400 s. Moreover, we tested the influence of human blood serum as a complex biological matrix on the way of determination of cisplatin. On the basis of the obtained results we estimated that we are able to determine tens of picomoles of cisplatin (5 mu l drop) in the presence of human blood serum.
Název v anglickém jazyce
Cisplatin electrochemical biosensor
Popis výsledku anglicky
Platinum complexes play an important role in the chemotherapy of various tumour diseases. The aim of this paper was to investigate if a metallothionein (MT) modified hanging mercury drop electrode can be applied as a cisplatin electrochemical biosensor.The modification of the mercury electrode surface by MT and the determination of cisplatin were performed by adsorptive transfer stripping technique and differential pulse voltammetry. The detection limit (3 S/N) of cisplatin ([Pt-II(NH3)(2)Cl-2](0)) calculated from the decrease of CdT peak was about 2.5 pmol in 5 mu l (0.5 mu M) at the interaction time of 400 s. Moreover, we tested the influence of human blood serum as a complex biological matrix on the way of determination of cisplatin. On the basis of the obtained results we estimated that we are able to determine tens of picomoles of cisplatin (5 mu l drop) in the presence of human blood serum.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP525%2F04%2FP132" target="_blank" >GP525/04/P132: Studium obranných mechanismů rostlin při stresu způsobeném těžkými kovy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrochim. Acta
ISSN
0013-4686
e-ISSN
—
Svazek periodika
51
Číslo periodika v rámci svazku
24
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
5169-5173
Kód UT WoS článku
—