Stanovení bromadiolonu v bažantech a liškách pomocí diferenční pulzní voltametrie
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F07%3A00020270" target="_blank" >RIV/00216224:14310/07:00020270 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62156489:43210/07:00107884 RIV/62157124:16270/07:00001308
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of bromadiolone in pheasants and foxes by differential pulse voltammetry
Popis výsledku v původním jazyce
Bromadiolone, a commercially used anticoagulant rodenticide, was determined in tissues of various animals by differential pulse voltammetry with a carbon-paste electrode. Under the most suitable experimental conditions (step potential of 25 mV s-1 and 0.2 mol L-1 acetate buffer, pH 4.2), the limit of detection was 0.5 ng mL-1. The electroanalytical method was consequently used to investigate the bromadiolone transport within the food chain. Pheasants were exposed to bromadiolone and then used as feed for a fox. The average levels were 528 and 198 ng of bromadiolone per gram of fresh weight of liver of pheasant and fox, respectively. Due to the surprisingly lower content of bromadiolone in the latter, a basic biochemical analysis, particularly blood coagulation, was performed. Among the parameters studied (thrombin time, prothrombin time, activated partial thromboplastin time, and fibrinogen), there was prolongation of the prothrombin time and activated partial thromboplastin time.
Název v anglickém jazyce
Determination of bromadiolone in pheasants and foxes by differential pulse voltammetry
Popis výsledku anglicky
Bromadiolone, a commercially used anticoagulant rodenticide, was determined in tissues of various animals by differential pulse voltammetry with a carbon-paste electrode. Under the most suitable experimental conditions (step potential of 25 mV s-1 and 0.2 mol L-1 acetate buffer, pH 4.2), the limit of detection was 0.5 ng mL-1. The electroanalytical method was consequently used to investigate the bromadiolone transport within the food chain. Pheasants were exposed to bromadiolone and then used as feed for a fox. The average levels were 528 and 198 ng of bromadiolone per gram of fresh weight of liver of pheasant and fox, respectively. Due to the surprisingly lower content of bromadiolone in the latter, a basic biochemical analysis, particularly blood coagulation, was performed. Among the parameters studied (thrombin time, prothrombin time, activated partial thromboplastin time, and fibrinogen), there was prolongation of the prothrombin time and activated partial thromboplastin time.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP525%2F04%2FP132" target="_blank" >GP525/04/P132: Studium obranných mechanismů rostlin při stresu způsobeném těžkými kovy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Environmental and Analytical Chemistry
ISSN
0306-7319
e-ISSN
—
Svazek periodika
87
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
11
Strana od-do
459-469
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—