Využití zinkové a železné emisní čáry pro analýzu hloubkového profilu pozinkovaného ocelového plechu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F07%3A00021925" target="_blank" >RIV/00216224:14310/07:00021925 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26210/07:PU63086
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The use of zinc and iron emission lines in the depth profile analysis of zinc-coated steel
Popis výsledku v původním jazyce
In this study we report on the results of experiments devoted to the depth profile analysis of zinc coated steel samples using LIBS (Laser Induced Breakdown Spectroscopy) technique. The dependence of zinc and iron emission in three ablation atmospheres (air, argon, helium) was measured using the fundamental wavelength (1064 nm) of the Nd:YAG laser. The highest possible depth resolution was achieved by optimizing the experimental parameters, such as the delay time (which affects the tailing of the zinc emission signal), focusing conditions, energy delivered to the sample, and choice of buffer gases. Current research indicates that there is a constant need to optimize these parameters so that reliable depth-profiling analysis can be performed.
Název v anglickém jazyce
The use of zinc and iron emission lines in the depth profile analysis of zinc-coated steel
Popis výsledku anglicky
In this study we report on the results of experiments devoted to the depth profile analysis of zinc coated steel samples using LIBS (Laser Induced Breakdown Spectroscopy) technique. The dependence of zinc and iron emission in three ablation atmospheres (air, argon, helium) was measured using the fundamental wavelength (1064 nm) of the Nd:YAG laser. The highest possible depth resolution was achieved by optimizing the experimental parameters, such as the delay time (which affects the tailing of the zinc emission signal), focusing conditions, energy delivered to the sample, and choice of buffer gases. Current research indicates that there is a constant need to optimize these parameters so that reliable depth-profiling analysis can be performed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Surface Science
ISSN
0169-4332
e-ISSN
—
Svazek periodika
253
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
3834-3842
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—