Multikanálový SPR biosensor pro detekci endoktrinních disruptorů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F07%3A00022878" target="_blank" >RIV/00216224:14310/07:00022878 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985882:_____/07:00307257
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Multichannel SPR biosensor for detection of endocrine-disrupting compounds
Popis výsledku v původním jazyce
A surface plasmon resonance (SPR) biosensor for simultaneous detection of multiple organic pollutants exhibiting endocrine disrupting activity, namely atrazine, benzo[a]pyrene, 2,4dichlorophenoxyacetic acid (2,4D) and nonylphenol, is reported. The biosensor utilizes a multichannel SPR sensor based on wavelength modulation of SPR and wavelength division multiplexing (WDM) of sensing channels, antibodies as biorecognition element and a competitive immunoassay detection format. An analysis time of 45 min (including 30 min incubation of the sample with antibodies) and limits of detection as low as 0.05, 0.07, 0.16 and 0.26 ng/mL are demonstrated for benzo[a]pyrene, atrazine, 2,4D and nonylphenol, respectively. The biosensor is also shown to be regenerableand suitable for repeated use
Název v anglickém jazyce
Multichannel SPR biosensor for detection of endocrine-disrupting compounds
Popis výsledku anglicky
A surface plasmon resonance (SPR) biosensor for simultaneous detection of multiple organic pollutants exhibiting endocrine disrupting activity, namely atrazine, benzo[a]pyrene, 2,4dichlorophenoxyacetic acid (2,4D) and nonylphenol, is reported. The biosensor utilizes a multichannel SPR sensor based on wavelength modulation of SPR and wavelength division multiplexing (WDM) of sensing channels, antibodies as biorecognition element and a competitive immunoassay detection format. An analysis time of 45 min (including 30 min incubation of the sample with antibodies) and limits of detection as low as 0.05, 0.07, 0.16 and 0.26 ng/mL are demonstrated for benzo[a]pyrene, atrazine, 2,4D and nonylphenol, respectively. The biosensor is also shown to be regenerableand suitable for repeated use
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
—
Svazek periodika
389
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
1841-1847
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—